Site Planning
78
Installation and Commissioning Manual
F
S
P
3000R
7 R
11
.1 8000
0015930
Issue
B
, ©
2012
ADVA AG Optical Netw
orking
ADVA Conf
idential
IEEE 1394 Interface Cable
To connect a 40CSM/2HU-#Dxx-#Dyy and a 40CSM/2HU-#19595-#19205 to
the PSCU, use the IEEE 1394 interface cable (IC300/PSCU/IEEE1394). The
ends of this cable are assembled with 6-pin male IEEE-1394 connector plugs.
The IEEE 1394 interface cable is 3 meters (9.84 feet) in length. It is delivered
along with the 40CSM/2HU-#Dxx-#Dyy and 40CSM/2HU-#19595-#19205.
SCU-Intercom-Kit
To connect SCU modules to each other, one SCU-Intercom-Kit is required. The
kit includes the following:
•
Four SFP transceivers (SFP/2G1/850I/MM/LC or
SFP/2G5U/1310S/SM/LC)
•
One multimode patch cable with duplex LC connectors on both ends
(J/MM62/LC/DUP/0090/RED) with a length of 90 cm (2.953 ft.)
•
One multimode patch cable with duplex LC connectors on both ends
(J/MM62/LC/DUP/0500/RED) with a length of 5.0 m (16.405 ft.)
The number of SCU-Intercom-Kits required depends on the network element
configuration. Use two pluggable transceivers and one patch cable with a length
of 90 cm (2.953 ft.) to establish an unprotected connection between two 9HU
Shelves, 7HU Shelves, 1HU Shelves, or 40CSM-OJG/3HU Shelves. The patch
cable with a length of 5.0 m (16.405 ft.) is used for a GbE SCU ring configura-
tion.
Table 16: Female HD SUB-D44 Connector Pinout
Female HD SUB-D44 connector
Pin Number
Relay No.
Signal
31, 16, 1
Relay 1
Output 1
32, 17, 2
Relay 2
Output 2
33, 18, 3
Relay 3
Output 3
34, 19, 4
Relay 4
Output 4
5, 20
Input 1
6, 21
Input 2
7, 22
Input 3
8, 23
Input 4
9, 24
Input 5
10, 25
Input 6
11, 26
Input 7
12, 27
Input 8
13, 28
Input 9
14, 29
Input 10
15, 30
Input 11
44, 43
Input 12
42, 41
Input 13
40, 39
Input 14
38, 37
Input 15
36, 35
Input 16
1
15
16
30
31
44