Installing a 40CSM/2HU Shelf
186
Installation and Commissioning Manual
F
S
P
3000R
7 R
11
.1 8000
0015930
Issue
B
, ©
2012
ADVA AG Optical Netw
orking
ADVA Conf
idential
Figure 41:
NEBS Bracket Fitted to the 40CSM/2HU-#D02-#D32 Shelf
Step 5
Repeat steps 3 to 4 of this procedure for the opposite side.
End of Procedure
Mounting the 40CSM/2HU Shelf into a Rack
This subsection describes the procedure that must be followed in order to mount
the 40CSM/2HU shelf to a rack or cabinet (in the following referred to as rack).
General Considerations
When mounting the 40CSM/2HU shelf to a rack, consider the following:
•
For information about mounting the 40CSM/2HU shelf to your rack, see the
instructions from the rack manufacturers.
•
Do not put any other shelf on the 40CSM/2HU shelf before mounting to the
rack. Every shelf should be mounted immediately after fitting the adaptor
brackets.
•
Avoid mounting the 40CSM/2HU shelf in an overly congested rack.
•
The 40CSM/2HU shelf can be mounted under or above a 1 HU or 7 HU
equipment shelf that it is serving. The shelf numbering does not change, i.e.
the 40CSM/2HU shelf does not have a shelf number.
•
The 40CSM/2HU shelf requires 2 HU (44.5 mm = 1.75 in) of space in the
rack.
CAUTION
Only Service Personnel are allowed to mount the 40CSM/2HU shelf
to a rack or cabinet.
Ensure that you are grounded with a wrist strap or equivalent while
mounting the brackets to a shelf which contains ESD-sensitive
devices.