Rack-Mounting the SH1HU/FIBERMANAGEMENT and the FMT/1HU Shelf
210
Installation and Commissioning Manual
F
S
P
3000R
7 R
11
.1 8000
0015930
Issue
B
, ©
2012
ADVA AG Optical Netw
orking
ADVA Conf
idential
When the cables are properly installed in the fiber management shelf, slack
loops will be formed within the shelf by the movement of the sliding radius limiter
with trumpet flare when the shelf is closed.
Tools and Parts Required
Kurly locks (only provided with the SH1HU/FIBERMANAGEMENT Shelf) are
required to locate and bundle fiber optic cables in a fiber management shelf:
To install fiber optic cables or patch cords in a fiber management shelf, perform
the following steps:
Procedure
Step 1
Open the tray by pushing the slide latches of the SH1HU/FIBERMAN-
AGEMENT or by loosening the screws of the FMT/1HU for access to
the fiber optic tray.
Step 2
Pulling out the tray completely. When the tray of the SH1HU/FIBER-
MANAGEMENT is completely open, the lock open latch is locked in
place.
Step 3
Route the cables to the open tray. The cables may be routed from
shelves rack-mounted above or below the fiber management shelf to
the left or right side of the fiber optic tray.
Step 4
Route the cables through the sliding radius limiter into the tray.
Whether the cables are routed through the left or right sliding radius
limiter depends on the configuration of the shelf from the which the
cables originate.
Step 5
Place the cables coming through the right sliding radius limiter around
the right set of storage radius limiters and the cables coming through
the left sliding radius limiter around the left set of storage radius limit-
ers.
In
a configuration of optical cables installed in an
SH1HU/FIBERMANAGEMENT is illustrated.
CAUTION
Infrared radiation is invisible. This can cause damage to the eye. Do
not look into the end of any open optical fiber connection.
NOTICE
Dirt particles can enter the optical fiber connector. Place
a protective cap over any open optical fiber connector.
NOTICE
Placing a load in excess of 9 kg (19.841 lb.) onto an open
tray will result in misalignment or damage to the tray.