Installing Pluggable Transceivers
250
Installation and Commissioning Manual
F
S
P
3000R
7 R
11
.1 8000
0015930
Issue
B
, ©
2012
ADVA AG Optical Netw
orking
ADVA Conf
idential
Step 10 Insert the desired CFP transceiver into the empty cage as follows:
NOTE: CFP transceivers are keyed so they can only be inserted in
one orientation.
a) Grasp the CFP transceiver so that the optical port is towards you,
and the label on the board cover as well as the host connector are
facing to the right.
Figure 73:
Example of Inserting a CFP Transceiver
b) Align the CFP transceiver into the empty interface cage, and
carefully slide it in until the CFP transceiver EMI gasket flange
makes contact with the bezel on the
channel module faceplate.
See
c) Press firmly on the front of the CFP transceiver with your thumbs
or fingers to fully seat it in the cage.
The CFP transceiver is completely inserted when its faceplate is
flush with the bezel on the channel module faceplate.
d) Gently tighten the two knurled screws on the CFP transceiver to
secure it in the cage.
P
S
Note
If you install a CFP transceiver into a WCC-PCTN-100G module, the
label on the board cover as well as the host connector must face to
the left.
P
S
Note
Insertion of a CFP transceiver is automatically detected by the
management software. Each time a transceiver is inserted into a cage
of a channel module, the internal network management system
receives a trap message.
Module type label
Optical port
Bezel