9-3
9
IM 701830-01E
Waveform Analysis
Setting the reference width (only when the cursor type is set to
“
UserDefine
”
)
Moving Cursors Ref1 and Ref2
7.
Press the “
Ref1/Ref2
” soft key and set the jog shuttle action to “
Ref1
.”
8.
Move Ref1 with the jog shuttle, and set the zero point.
9.
Similarly, move Ref2 and set the end point.
Setting the reference width
10.
Press the “
Reference Value
” soft key and set the jog shuttle action to “
Reference
Value
.”
11.
Set the reference width with the jog shuttle.
Setting the unit
12.
Press the “
Unit
” soft key to display the keyboard.
13.
Set the unit. You can enter up to three characters.
→
Moving the cursor
14.
Press the “
Cursor2
” soft key.
Cursor 1 can now be moved using the jog shuttle.
15.
Turn the jog shuttle to move cursor 1.
16.
If “
Linkage
” was set to OFF in step 6, move Cursor 2.
If “
H & V
” was selected in step 3, move Cursor 3 and Cursor 4 as well.
Marker cursor jump (Available only if cursor type is Marker)
4.
Press the “
Jump Type
” soft key the appropriate number of times to select the marker you
wish to jump and its destination.
5.
Pressing the “
Marker Jump
” soft key moves the marker to the destination screen.
Turning ON/OFF the function to move the two cursors simultaneously
Press the “
Linkage
” soft key and select “
ON
” or “
OFF
.”
Note
The menu varies depending on the selected cursor type.
9.1 Measuring Waveforms using Cursors