6-11
6
IM 701830-01E
Triggering
Setting the condition A
4.
Press the “
Set Pattern
” soft key to display the A
→
B(n) trigger setting menu.
5.
Turn the jog shuttle to move the cursor to the <Parallel A> “Condition.”
6.
Press the
SELECT
key to display the <Parallel A> “Condition” menu.
7.
Press the
SELECT
key to select “
Enter
” or “
Exit
.”
→
Setting the channel status for condition A
8.
Turn the jog shuttle to move the cursor to “
CH1
.”
9.
Press the
SELECT
key to display the CH1 menu.
10.
Press the same
SELECT
key the appropriate number of times to select from “
H
,” “
L
” and
“
X
” (“
O
” and “
X
” for logic input).
11.
Repeat the above steps to set the channel status for CH2 to CH16.
When the channel is
a Logic Input Module
Setting the condition B and channel status
12.
Repeat steps 5 to 11 to set the condition B and channel status.
Setting the condition B repeating count
13.
Turn the jog shuttle to move the cursor to “
N Count
.”
14.
Press the
SELECT
key to display the “
N Count
” menu.
15.
Turn the jog shuttle to set the desired repeating count (n) for condition B.
You can change the value of the digit using the cursor key (located below the jog shuttle).
Pressing the
RESET
key, resets the repeating count to “
1
.”
Setting the conditions of POD A and B (when using the logic input channel only)
16.
Press the “
Bit Pattern
” soft key. (This key is not displayed unless logic input channel is
selected with “
Select CH
.”)
17.
With the jog shuttle, move the cursor to the bit to which you wish to set the condition.
18.
Press the
SELECT
key to select “
H
,” “
L
,” or “
X
.”
Other settings
19.
You must also set the following parameters: trigger mode, trigger level, trigger hysteresis,
and holdoff time. For information about how to set these parameters, refer to Sections 6.1 to
6.7.
Note
Status settings for conditions A and B apply in common to all trigger types.
6.9 Setting the A
→
B (n) Trigger (ENHANCED)
Setting the status of
each bit on the logic
input channel