• Custom and other size papers
Important:
To identify the fuser type and set minimum and maximum NVM width values,
inform the system administrator. The administrator must set the NVM settings from Tools
mode on the press control panel. When using a bypass connector with the fuser, the press
detects the fuser type and width and confirms it is appropriate for the system.
Note:
The bypass connectors required for each fuser width type are located in the
nationalization kit which come with the press. To order additional fusers for this product,
contact your Customer Support Center.
WARNING:
Before you perform this procedure, power off the press and allow fifty minutes for
the fuser to cool down. Always observe the warning labels inside the press.
1. If required, have the system administrator update the NVM width range settings for the fuser
from Tools mode and identify the specific width range of media that can be run through the
fuser.
Refer to the
System Administrator Guide,
Default and Custom Paper Width Settings
tables in
the
Using the Fuser NVM Read/Write Setting
procedure. Always set the NVM settings before
using the new fuser.
2. Open both the left and center front doors.
3. Locate the black fuser front cover.
4. Remove the fuser front cover by using the T10 Torx driver to unscrew the one mounting screw at
the center of the cover.
269