b.
Install a new
nudger roll
by squeezing the metal shaft at both ends and sliding it into place.
5. Remove the
separator roll
and install a new one.
a.
Remove the
separator roll
by squeezing the metal shaft at both ends and lifting it up and
out of the tray.
b.
Install a new
separator roll
by squeezing the metal shaft at both ends and sliding it into
place.
6. Close the bypass tray cover.
7. Verify that the tray is operating correctly by feeding paper from the bypass tray.
8. Log in as the administrator or ask the administrator to perform the following steps to reset the
High Frequency Service Item (HFSI) count to zero (0):
a.
At the control panel, press the
Tools
button.
b.
From the screen that displays, select the
Tools
icon.
c.
Select
System Settings > Common Service Settings > Maintenance
.
d.
Use the arrow buttons to access the next Maintenance screens.
254