Executing Calibration
67
M
ai
n
te
na
nc
e
3
9
Align the magenta patch of the
printed Calibration Chart against
the left side of the document glass.
Note
•
Place the Calibration Chart on
the document glass.
10
Put at least five sheets of white
paper over the Calibration Chart
and close the document cover.
11
Select [Start].
The message
"Calibration is in progress. Copy Job" appears and the machine
automatically adjusts the gradation. It takes about 20 seconds to complete the
gradation adjustment.
When the adjustment is completed successfully, the [Calibration] screen (for screen
type settings) appears again. If there is a problem, the machine stops the adjustment
and displays an error message. Solve the problem in accordance with the displayed
error message.
12
Select [Confirm]. To continue automatic calibration for other screen types, repeat
steps 6 to 12.
13
Select [Close] repeatedly until the [Tools] screen is displayed.
14
Select [Close] to exit the [Tools] screen.
15
Make a copy to check the image quality.