Time Zone
Specifies the time different from Greenwich Mean Time (GMT).
Daylight Savings
Select [Adjust Off], [Adjust by Day, Month & Time], or [Adjust by Month, Week, Day of Week
& Time].
If [Adjust by Day, Month & Time] is selected, you can specify and set the month, day, and
time for [Start Date] and [End Date].
If [Adjust by Month, Week, Day of Week & Time] is selected, you can specify and set the
month, week, day of week, and time for [Start Date] and [End Date].
NTP Time Synchronization
You can obtain the time from a time server (NTP: Network Time Protocol), to synchronize the
machine time to the server time.
If you connect to a time server, select [On] for [Connection to Time Server], and set the IP
address of the time server in [Time Server Address].
Connection Interval
Select the time interval at which a connection is made to the time server.
Select an interval from 1 to 500 hours in 1 hour increments.
Time Server Address
Set the IP address of the time server from which the time is obtained, using values 0 to 255.
Note
•
For IPv4, enter the address in the format "xxx.xxx.xxx.xxx", where "xxx" is a numeric value in
the range of 0 to 255.
•
For IPv6, enter the address in the format "xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx", where
"xxxx" is a hexadecimal value.
Auto Clear
Specify how many seconds should elapse with no operation before automatic reset occurs.
When [On] is selected, specify a value between 30 and 900 seconds, in 1 second increments.
In order not to set this feature, select [Off].
Note
•
Even if [Off] is selected, when there is no operation for 1 minute on the screen waiting for a
job command after scanning, the machine cancels the waiting condition and starts to
process the scanned documents.
Auto Job Release
If an error occurs (document or paper jams, running out of paper, etc.) during copying or
scanning, the machine cancels the active job and starts the next job after a given period of
time. In that case, jobs that can be activated are limited to those that only use parts of the
machine not affected by the error.
When [On] is selected, specify a value between 4 and 99 minutes, in 1 minute increments. In
order not to set this feature, select [Off].
Auto Print
Set the time period to start the next print job after finishing a copy operation.
When [On] is selected, specify a value between 1 and 240 seconds, in 1 second increments.
If you select [Off], printing starts immediately after the machine is ready.
Printer Lockout Duration
The machine disables to print during a given period of time.
If you selected [On], specify a starting time and an ending time to disable printing, in one
minute increments.
Note
•
A job which has already been activated before the starting time will be printed continuously