background image

Using Spectrum Analyzer 

60 

Total harmonic distortion measurement with spectrum analyzer 

 

 

Field strength meter 

The Field Strength Meter measures the field strength over the frequency range of a connected antenna, which is known with its 
specific bandwidth and gain characteristics. A standard or user-defined antenna can be selected from the antenna list in the 
CellAdvisor 5G. After configuring spectrum measurement in "

Configuring Spectrum Measurements

", you can set the measure setup 

to continue your measurement. 

Setting measure setup 

1

      

Connect an antenna to be used with your instrument. 

2

      

Tap the 

Setup

 (

) icon on the side bar. 

3

      

Tap 

Antenna List

 to select antennas to be used for field strength measurement from the list stored in the instrument. 

The antenna list window appears. 

4

      

Tap the 

Apply

 button to apply the selection. 

5

      

Tap 

Antenna Start Frequency

 to edit the start frequency of the connected antenna using the on-screen keyboard. 

6

      

Tap 

Antenna Stop Frequency

 to edit the stop frequency of the connected antenna using the on-screen keyboard. 

7

      

Tap 

Gain

 to input the gain information of the antenna using the on-screen keyboard. 

Setting limit 

You can show or hide the display line on the screen that is used as a visual reference only. You can also use the multiple segment 
limit line to set up different limits for different frequency ranges for Pass/Fail indication. 

1

      

Tap 

Menu

 > 

Limit

2

      

For details, see "

Setting limit

". 

Summary of Contents for CellAdvisor 5G

Page 1: ...1 CellAdvisorTM 5G User s Guide ...

Page 2: ......

Page 3: ..._________________ 11 Unpacking and inspecting the CellAdvisor 5G 11 Accessories 11 Exploring the CellAdvisor 5G 12 Top panel 12 Side panel 13 Installing battery 14 Installing battery 14 Powering the instrument 15 Using the AC power adapter 16 Turning on the instrument 16 Turning off and rebooting the instrument 16 Navigating the user interface 17 Starting the CellAdvisor 5G 17 Operating CellAdviso...

Page 4: ...VG 43 Setting sweep 44 Sweep 44 Setting trigger 45 Trigger 45 Setting trace 46 Trace 46 Setting limit 47 Limit 48 Using marker 49 Marker 49 Conducting spectrum measurements 51 Sweep tuned spectrum 51 Conducting RF measurements 51 Channel power 51 Occupied bandwidth 52 Spectrum emission mask SEM 54 Adjacent channel power ACP 55 Multi adjacent channel power 56 Spurious emissions 58 Total harmonic di...

Page 5: ...______________________ 99 Introduction 99 Selecting mode and measure 100 Conducting spectrum measurement 100 Spectrum 100 Conducting RF measurement 101 Channel Power 101 Setting measure setup 101 Setting limit 101 Occupied bandwidth 102 Setting measure setup 102 Setting limit 102 Spectrum Emission Mask SEM 103 Setting measure setup 103 Setting limit 103 ACLR 104 Setting measure setup 104 Setting l...

Page 6: ... Setting measure setup 124 Control Channel 125 Setting measure setup 125 Setting limit 126 Datagram 126 Setting measure setup 126 Route Map 127 Loading a map 127 Setting measure setup 128 Logging data 128 Viewing the logging data 128 Setting limit 129 Importing cellsite DB 129 Freq Time Power Variation 131 Miscellaneous 132 Power Statistics CCDF 133 Setting measure setup 133 8 Using LTE LTE A TDD ...

Page 7: ...measure setup 147 Setting limit 148 Using marker 148 Control Channel 149 Setting measure setup 149 Setting limit 150 Subframe 150 Setting measure setup 151 Setting limit 152 Using marker 152 Time Alignment Error 152 Setting measure setup 153 Setting limit 153 Data Allocation Map 153 Setting measure setup 154 Setting display 154 Using marker 154 Carrier Aggregation 155 Setting measure setup 155 Set...

Page 8: ...175 Selecting mode and measure 175 Conducting OTA measurements 175 Beam analyzer 175 Setting measure setup 175 Carrier scanner 176 Setting measure setup 176 Route map 178 Loading a map 178 Setting measure setup 179 11 Using 5G NR Signal Analyzer ________________________________________________________________ 182 Introduction 182 Selecting mode and measure 183 Conducting spectrum measurement 183 T...

Page 9: ...ation 224 Setting measure setup 224 Setting limit 227 EVM vs Subcarrier 228 Setting measure setup 229 Allocation mapper 233 Setting measure setup 233 12 Using NSA Signal Analyzer __________________________________________________________________ 237 Introduction 237 Selecting mode and measure 237 Conducting OTA measurements 237 NSA analyzer 237 Setting measure setup 238 NSA scanner 241 Setting mea...

Page 10: ...Control channel 268 Setting measure setup 268 Setting limit 270 Subframe 272 Setting measure setup 272 Setting limit 273 Using Marker 275 Frame 277 Setting measure setup 277 Setting limit 278 Time alignment error 280 Setting measure setup 281 Conducting OTA measurements 282 OTA channel scanner 282 Setting measure setup 282 Setting Limit 284 OTA ID scanner 285 Setting measure setup 285 OTA multipat...

Page 11: ...n quality 313 Setting measure setup 314 Setting limit 314 MIMO time alignment error 315 Setting measure setup 315 Setting limit 316 CA time alignment error 317 Setting measure setup 318 Setting limit 318 15 Using Power Meter _________________________________________________________________________ 321 Introduction 321 Selecting mode and measure 321 Internal RF power meter 321 Setting measure setup...

Page 12: ...parameters 333 Setting measure setup 335 Conducting spectrum measurement 336 Conducting spectrogram 337 Performing spectrum replayer 338 Setting Display 339 17 Appendix _________________________________________________________________________________ 341 A Ordering information 341 CA5000 CellAdvisor 5G 341 B RoHS information 343 ...

Page 13: ...is a trademark or a registered trademark of Google in the United States and or other countries iOS is a trademark or a registered trademark of Apple Inc in the United States and or other countries All other trademarks and registered trademarks are the property of their respective owners Copyright release Reproduction and distribution of this guide is authorized for US Government purposes only Term...

Page 14: ... la norme ICES 003 du Canada This device complies with Industry Canada license exempt RSS standard s Operation is subject to the following two conditions 1 this device may not cause interference and 2 this device must accept any interference including interference that may cause undesired operation of the device Device operation in the band 5150 5250 MHz is for indoor use only Le présent appareil ...

Page 15: ...equency bands and the maximum RF transmit power of this product for sale in the EU Frequency range MHz Channels Used Max Transmit Power dBm mW 5470 5725 100 140 29 9 dBm 977 mW with TPC 26 9 dBm 490 mW non TPC 5250 5350 52 64 22 9 dBm 195 mW with TPC 19 9 dBm 97 7 mW with TPC 5150 5250 36 48 22 9 dBm 195 mW 2400 2483 5 1 13 ODFM 19 9 dBm 97 7 mW CCK 17 9 dBm 61 7 mW TPC Transmit Power Control Guid...

Page 16: ... or the packaging indicates that the equipment or battery must not be disposed of in a land fill site or as municipal waste and should be disposed of according to your national regulations Safety definitions Term Definition NOTE Indicates important supplemental information or tips related to the main text DANGER Indicates a potentially hazardous situation that if not avoided will result in death o...

Page 17: ...hnical assistance If you require technical assistance call 1 844 GO VIAVI or send an email to TAC viavisolutions com For the latest TAC information go to http www viavisolutions com en services and support support technical assistance ...

Page 18: ......

Page 19: ...G is designed to be rugged portable touch based and battery operated test solutions that facilitate the quick turn up and validating 5G radio access The CellAdvisor 5G addresses spectrum analysis interference analysis and signal analysis using the 5G technology with FR1 and FR2 bands Main features of the CellAdvisor 5G CA5000 are as below Full flexibility to test multi radio access technologies fr...

Page 20: ...zer assessing individual beam s ID its power level and corresponding signal to noise ratios 5G route map for coverage verification mapping the beam strength in real time as well as making data available for postprocessing Specifications The physical power supply battery and environmental characteristics for the CellAdvisor 5G are listed in the tables below Physical specifications Product Dimension...

Page 21: ...ronment with low humidity Environmental specifications You can check the environment specifications in the following table Item Descriptions Maximum Humidity 95 RH non condensing Shock and Vibration MIL PRF 28800F Class 2 Drop MIL PRF 28800F Class 2 Storage Temperature 20 to 60 C Data storage You can check the data storage specifications in the following table Item Descriptions Internal Maximum 4 ...

Page 22: ......

Page 23: ...w to use the LCD protector see the Quick Start Guide provided with the instrument Accessories The following standard accessories are shipped with the instrument Optional accessories can be also purchased when needed Standard accessories Item Description CA5000 CellAdvisor 5G A base unit Software and Hardware options are also available which enable you to expand your testing capabilities AC DC adap...

Page 24: ...enna is a WR 28 waveguide with UG 599 U flange The Horn Antenna Kit consists of Horn Antenna and WR 28 Waveguide Adaptor Omni directional Antenna K f 26 GHz to 40 GHz G700050340 It is a full band Ka band omnidirectional antenna that covers the frequency range of 26 5 and 40 GHz This vertically polarized antenna offers 360 degrees azimuth coverage with a 3 dBi typical gain and 1 dB nominal gain fla...

Page 25: ... with a headphone icon It is a 3 5 mm size mono jack Plugging in specified headset with integrated microphone turns unit internal speaker off 8 POWER button Use the power button to turn your CellAdvisor 5G on or off When external power is supplied via the AC DC adapter the LED is illuminated based on the battery status 9 SFP SFP ports The optical hardware option board Option O001 for RFoCPRI suppo...

Page 26: ...s port is to supply power via AC DC power adapter provided with your instrument NOTE You need to open the led located between the cooling fans on the right side panel to use ports Installing battery You need to install the Lithium Ion battery pack provided with your instrument Follow the instruction to install batteries Installing battery 1 Lay the unit on the back side with the LCD facing up 2 Un...

Page 27: ...our local safety and environmental regulation NOTE It is recommended that you turn off the instrument to replace the battery However if you do not want to interrupt the current test you can leave the module tuned on with the AC power adapter plugged in Powering the instrument Power is supplied to the instrument by the battery or the AC power adapter For the CellAdvisor 5G the adapter is supplied w...

Page 28: ...le shows the LED indication when the unit powered on or in hibernate mode Battery status LED color Battery charging The LED color is amber red green The unit can be either On or Off Battery fully charged The LED color is green Battery low The LED color is red Make sure the instrument is not powered by AC adapter Turning off and rebooting the instrument 1 Press the ON OFF button for approximately1 ...

Page 29: ... Module This indicates that the current active module It may have more tabs when the external module is attached If there are no other modules attached only the internal tab is displayed 2 Title edit box Tap the Edit icon to change the title name using the on screen keypad The default name is test 3 Measurement panel Tap to select measurement that you want to measure 4 Cancel Done button Tap the C...

Page 30: ... 4 Sync This is a Sync indicator When the signals are demodulated and received correctly it displays green and otherwise red 5 Pass and Fail This is a pass and fail indicator for the measurement result It is activated only when you turn the Limit on 6 Add button This is an icon that creates a new measurement tab 7 Side bar This is a menu set which includes all parameters that you can set for the s...

Page 31: ...rovides test parameters to set for the selected measure You can simply tap it and set the parameters Method 3 The third icon Full Menu on the Side bar provides test parameters to set for the selected measure You can simply tap it and set the parameters Method 4 CellAdvisor 5G provides you with finger touch gesture operation for the Center Frequency Span Frequency and Reference Level For how to use...

Page 32: ...enu pops up on the right side Limit Tap to set the Limit related parameters The Limit menu pops up on the right side Marker Tap to set the Marker related parameters The Marker menu pops up on the right side Menus on the side bar Items Name Description Menu Tap to view all menus for the selected measurement and mode Note that the Menus vary based on the selected measurement and mode Setup Tap to vi...

Page 33: ...Last or Preset You can tap the Factory Reset button to reset your instrument If you need to select multi frequency or multi channel in your measurement mode make sure to switch this to On default This enables you to select multi frequency and multi channel using the pop up windows The Global 30 days options are also available in the System Setting screen Self Test for main board and RF calibration...

Page 34: ... into the internal memory or your external USB memory drive USB A or USB B or SD card To see the storage location tap the Folder icon Make sure to insert a USB memory drive to USB A or B port and insert the SD card to MicroSD port to enable the option When you are using the Save feature Hold is automatically enabled There are two ways that you can access Save Method 1 Tap the first Menu icon on th...

Page 35: ...rt Setup box 2 Insert the company image using the icon 3 Enter the company name in the Company Name Here field 4 Enter the name of the person who performed testing in the Your Name Here field 5 Enter your company or site address in the Address field 6 Enter a description about the site or place in the Site Information field 7 Enter your test purpose in the Test Purpose field 8 Enter a summary of y...

Page 36: ...ile appears in the File Information pane 2 Check the file information on the right pane 3 Tap the Load button to load the file Using file manager The CellAdvisor 5G lets you create a user defined folder select copy cut paste and delete data files saved in the internal memory or in your USB memory drive You can manage your data files using the icons below Items Name Description Select Tap the Folde...

Page 37: ...ou want to apply 4 Tap the Apply button NOTE You can also rename or delete the selected file by using the Rename or Delete icon on the cotton left screen Managing a favorite group file You can manage a favorite group file using the Favorite Group menu 1 Tap the Favorites icon on the side bar 2 Tap the Group icon you want from Group A to Group R to get focus highlighted in purple 3 Tap the Rename i...

Page 38: ...ystem pages You can return to the Home screen at any time by clicking the Home button in the top left corner of the screen Favorites The Favorites page provides access to pages identified as Favorites and the most recent pages visited Tests The Tests page provides access to the available tests ...

Page 39: ...o specify the information to be included whenever you run a test and generate a report Each time you generate a report your instrument will automatically insert the Customer Name Job Number Technician ID and Test Location that you specified in the Job Manager into the report heading ...

Page 40: ...ort Info screen the Work Order number will be included in your report output instead of the default Job Number To specify report information 1 On the Home screen select Job Manager The Job Manager screen appears 2 Specify the Customer Name Job Number Technician ID and Location The report information is specified and will be retained until you change it System The System screen provides access to t...

Page 41: ...ndard changes automatically 5 In the Samples for selected formatting box the date time and number formatting appear 6 To change the formatting standard click the Change formatting standard box and select a country 7 In the Customize box click the check box next to Use 24 hour time 8 Turn the instrument off then back on The user interface changes to the language you specified Setting the date and t...

Page 42: ...ss password To change the default password do the following steps 1 Select the System icon The System screen appears 2 Select the Remote VNC icon 3 Tap the Remote access password filed then specify a new password using the on screen keyboard 4 Optional Tap the check box for Enable Firewall if you wish to do so 5 Optional Tap the check box for Enable VNC access if you wish to do so 6 Optional Tap t...

Page 43: ... device enter a pairing code if prompted and then select Pair to pair it with the instrument Checking the battery You can check the status of the battery in two ways Method 1 The battery status indicator in the upper right corner of the screen provides a graphic indication of the approximate battery charge Method 2 The Battery Level percentage on the Battery status page 1 Select the System icon Th...

Page 44: ... number of minutes of delay 5 Tap the check box next to Screen saver password if you wish to enable a screen saver password a password is required to close the screen saver and resume using the instrument Make a note of the password and put it somewhere safe The screen saver is setup Using the clock source The Clock Source is used as a reference frequency and timing source for the CellAdvisor 5G a...

Page 45: ...ect the desired Survey Mode from the following choices Dynamic Continuously calculates positioning for continuous location information Auto Calculates positioning until accurate location information is determined and switches to fixed position using accurate location information and switches to determine timing accuracy 6 In Elevation Limit deg specify the elevation limit in degrees This value rep...

Page 46: ...ation is available only if GNSS is On Lock Status Searching Lock Status Locked Viewing the System Info To view the revisions of internal components and to see which options are enabled use the System Info menu This menu also provides the serial number of the instrument and serial numbers of internal components The Copy System Info to File button is used to save a file that includes all the system ...

Page 47: ... instrument and check the option is installed Updating the software System Software and Solution Firmware upgrades can be loaded from storage media such as a USB memory stick and over the network To obtain the latest software release for your unit visit VIAVI Software Updates website and check if your installed software and firmware are the latest ones The CellAdvisor 5G software can be updated in...

Page 48: ...to the USB software release number If the release is an upgrade a later software release than that installed on your instrument an up arrow will be displayed next to the USB software release number 6 Select Start Upgrade A dialog box appears instructing you to exit any existing tests You have the option to cancel the upgrade at this point for example if you need to complete a test that you are cur...

Page 49: ...ase is a retrograde an earlier software release than that installed on your instrument a down arrow will be displayed next to the USB software release number If the release is an upgrade a later software release than that installed on your instrument an up arrow will be displayed next to the USB software release number 7 Select Start Upgrade A dialog box appears instructing you to exit any existin...

Page 50: ...ing to sync to the server 4 Enter an optional Tech ID This will be populated by a default value representing your test instrument but can be changed to identify the user who is initiating the synchronization 5 Tap the Start Sync button 6 Go to the stratasync viavisolutions com via internet connection NOTE During Synchronization a cloud icon will be displayed at the top of the screen and the state ...

Page 51: ... interference with adjacent frequency bands The Adjacent Channel Power Ratio ACPR characteristic of a power amplifier or other RF components is an important factor in evaluating the system performance Spectrum analyzer in CellAdvisor 5G has three measure categories as the following with frequency extension up to 18 5 GHz in addition to existing 24 GHz to 40 GHz Spectrum Analysis Sweep Tuned spectr...

Page 52: ...top frequency values appear below the graticule on the display If you are aware of the frequency of the signal you are going to measure the best option is to match the center frequency to the signal s frequency If you are investigating signals for example harmonics distortion that are within a particular frequency range it is best to enter a start and stop frequency to define the span Access on th...

Page 53: ...ro Span select Trigger Free External GPS or Video Access Menu Frequency Zero Span Last Span Sets the span to the previous span setting Access Menu Frequency Last Span Setting channel Almost all transmission systems divide their assigned frequency ranges into channels Each channel corresponds to a specific frequency To easily operate such systems you can use channel standard table instead of settin...

Page 54: ...on and the maximum value can be set up to 20 dB Set the value using the on screen keyboard Access Menu Amp Scale Scale Division Scale Unit Tap to change the scale unit of the display scale dBm dBV dBmV dBμV V or W Access Menu Amp Scale Scale Unit Preamp 1 On Off Allows you to turn the internal pre amplifier on to correct and compensate for the gain of the preamp so that amplitude readings show the...

Page 55: ... to your frequency span setting for RBW and to the current RBW and VBW RBW settings for VBW Access on the Quick access and display tab or Menu BW AVG BW AVG The following is the definition of each key function Parameter Definition RBW Tap RBW to set it manually Tap a value between 1 Hz to 3 MHz The RBW setting automatically changes to Manual Access Menu BW AVG RBW RBW Mode Manual Auto Toggle the R...

Page 56: ...u can change the sweep mode Access on the Quick access and display tab or Menu Sweep Sweep The following is the definition of each key function Parameter Definition Sweep Time Shows the sweep time when the sweep time is set to Auto If the sweep time is set to Manual you can manually input the sweep time using the on screen keyboard Menu Sweep Sweep Time Sweep Time Mode Manual Auto Select the sweep...

Page 57: ...rtain signal conditions you can use a trigger A trigger responds to certain events When using a trigger source other than Free the CellAdvisor 5G starts to sweep only with the selected trigger conditions are met The trigger can be generated either externally or internally Access on the Quick access and display tab or Menu Trigger The following is the definition of each key function Parameter Defin...

Page 58: ...ccess Menu Trace Trace View On Off Trace Type Tap to select the Trace Type from the following options Clear Write Capture Max Min or Load For details refer to Trace type below Access Menu Trace Trace Type Trace Hold Time Tap to set the Trace Hold Time using the on screen keyboard Access Menu Trace Trace Hold Time Select Trace Info Tap to select the trace information from the following options None...

Page 59: ... once selected the Trace Legend L is indicated on the Quick access and display tab for Trace NOTE For the Max Hold and Min Hold your instrument compares newly acquired data with the active trace and displays larger maximum values or smaller minimum values on the screen Trace detection Normal Displays random noise better than the peak without missing signals Peak Displays the highest value in each ...

Page 60: ...to 50 segments using the on screen keyboard 5 Tap Autoset soft key to automatically set the limit for each segment and display the line 6 Tap Offset Up Down or Offset Left Right to move the limit line using the on screen keyboard The following table shows the parameters displayed for the multi segment line Parameter Definition Autoset Tap to autoset the limit for each segment and display line Acce...

Page 61: ... each measurement There are three different marker types available Normal Delta and Delta pair Marker position can be set manually by entering numeric values frequency or using the purple move bar when one of the marker types is selected Access on the Quick access and display tab go to Menu Marker or tap the hot key icon Marker The following is the definition of each key function Parameter Definit...

Page 62: ...hen the Marker View is selected for those markers the instrument displays those markers back at the previous position If a measurement mode is changed current settings are not restored Start Sets the frequency of the active marker to the start frequency of spectrum analyzer Center Sets the frequency of the active marker to the center frequency of spectrum analyzer Stop Sets the frequency of the ac...

Page 63: ...n test used in the wireless industry to measure the total transmitted power of a radio within a defined frequency channel It acquires a number of points representing the input signal in the time domain transforms this information into the frequency domain using Fast Fourier Transform FFT and then calculates the channel power The effective resolution bandwidth of the frequency domain trace is propo...

Page 64: ...l is red 3 Tap High Limit to set the upper threshold using the on screen keyboard 4 Tap Low Limit to set the lower threshold using the on screen keyboard 5 Optional Tap the Save hot key on the side bar and select the save option form the choices available for your measurement mode Channel power measurement with spectrum analyzer Channel power measurement result shows channel power and spectrum den...

Page 65: ...input value range is from 1 to 100 Setting Limit 1 Tap Menu Limit 2 Tap to switch the Test Limits to On or Off to enable or disable Pass Fail indication The result table color for Pass is green and the result table color for Fail is red 3 Tap High Limit to set the upper threshold using the on screen keyboard 4 Optional Tap the Save icon on the side bar and select the save option form the choices a...

Page 66: ...fset from 1 to 5 and switch each to On to display or Off to hide the active offset b Select Offset Frequency to set the start frequency of SEM using the on screen keyboard c Select Measurement Bandwidth to set the bandwidth for the selected offset using the on screen keyboard d Switch the Reference to Relative or Absolute depending on how to use the reference e Select Start Limit to set the start ...

Page 67: ...to determine whether the carrier power is set correctly and whether the transmitter filter is working properly You can measure the channel power in from one to five adjacent offset channels on the lower frequency and upper frequency side of the carrier channel Limits can be used to quickly see if too much power is measured in the adjacent channels Setting measure setup After configuring spectrum m...

Page 68: ...r Trace Threshold Auto and Threshold RMS Level An offset represents a difference in center frequencies of the carrier channel and its adjacent channel to be measured The frequency range for each offset is specified with an Offset Frequency and Integration BW Each offset that is created has a Lower and Upper set of frequencies NOTE Make sure the Detector is selected to RMS when you perform the adja...

Page 69: ...t the value using the on screen keyboard You can also tap the rectangle with value under the chart screen and input the value using the on screen keyboard 5 For channel setting tap Highest Channel Number and input the value using the on screen keyboard 5 For frequency setting tap Lowest Frequency and input the value using the on screen keyboard You can also tap the rectangle with value under the c...

Page 70: ...ap to switch the Measure Type to Full or Examine NOTE The Examine mode displays only the selected range while the Full mode lets the instrument automatically changes the selected range from one another 3 Tap Configuration to set up the range table and parameters as below a Select Range from 1 to 20 and switch each to On to display the selected range in the result table or Off to hide it from the t...

Page 71: ...Advisor 5G can measure the Total Harmonic Distortion using spectrum analyzer The Total Harmonic Distortion is defined as the ratio of RMS voltage of the harmonics to that of the fundamental component This is accomplished by using a spectrum analyzer to obtain the level of each harmonic with peak detector Setting measure setup You need to set the fundamental frequency to measure the total harmonic ...

Page 72: ...on the side bar 3 Tap Antenna List to select antennas to be used for field strength measurement from the list stored in the instrument The antenna list window appears 4 Tap the Apply button to apply the selection 5 Tap Antenna Start Frequency to edit the start frequency of the connected antenna using the on screen keyboard 6 Tap Antenna Stop Frequency to edit the stop frequency of the connected an...

Page 73: ... the duration of the measurement before it is interrupted and the next gate signal is expected to resume the measurement The measurement settings can be saved and recalled as a file by selecting File Type as Setup and load the file onto the instrument using the Save Load icons on the side bar Gate sweep spectrum setup screen Setting Gate Sweep Spectrum The above figure is the first screen you will...

Page 74: ...ls that can be heard through the built in speaker or plugged in headphones You can hear the sound and identify interfering signals easily Setting measure setup After configuring spectrum measurement in Configuring Spectrum Measurements you can set the measure setup to continue your measurement The measurement settings can be saved and recalled as a file by selecting File Type as Setup and load the...

Page 75: ... related to maps you need to download and install the maps on the CellAdvisor 5G The VIAVI JDMapCreator will help you download maps Make sure the JDMapCreator application on your computer is connected to the instrument via LAN You can send a map file with a single layer to the instrument directly by using the Send to EQP menu in JDMapCreator For more information on how to use the JDMapCreator see ...

Page 76: ... ACP is selected set the Main Channel BW and Offset Limit a Tap Main Channel BW and input a value using the on screen keyboard b Tap Offset Limit and tap to switch the Offset to On to display or Off to hide the offset c Tap Integration Bandwidth and input a value using the on screen keyboard d Tap Offset Frequency and input a value using the on screen keyboard e Tap Offset Limit and input a value ...

Page 77: ...nt color indicators red and blue The maximum value is the Limit for Excellent and the minimum value is the Limit for Poor See below to check the plot point color based on the Legend Color Table 1 Tap the rectangle with value before color legend bar on the right panel 2 Set a value for Poor minimum value using the on screen keyboard 3 Tap the rectangle with value after color legend bar on the right...

Page 78: ...Using Spectrum Analyzer 66 NOTE When you tap the Start Testing button the corresponding power will show on the measurement screen ...

Page 79: ... The CellAdvisor 5G is extremely effective for locating and identifying periodic or intermittent RF interference Interference signals derive from several kinds of licensed or unlicensed transmitters that cause dropped calls and poor service quality The CellAdvisor 5G provides following measurements for interference analysis with frequency extension up to 18 5 GHz in addition to existing 24 GHz to ...

Page 80: ...Line to specify a threshold for the reference line using the on screen keyboard e Optional To adjust the volume for alarm sound tap Volume and input from 1 to 10 using the on screen keyboard Setting measure setup for Interference ID The Interference ID automatically classifies interfering signals over a designated spectrum and displays the list of possible signal types corresponding to the selecte...

Page 81: ...ove the time cursor by inputting a value using the on screen keyboard 5 Tap Type to switch the chart view type 3D Display or Normal You can also change the cart view type using the icon on the chart screen 6 Tap Reset Restart to start a new measurement NOTE Enabling the time cursor puts the measurement on hold and you can make postprocessing analysis for each measurement over time using the time c...

Page 82: ...ectrogram and RSSI measurements can be automatically saved into an external USB memory Setting measure setup After configuring spectrum measurement in Configuring Spectrum Measurements you can set the measure setup to continue your measurement 1 Tap the Setup icon on the side bar 2 Tap Alarm to set the alarm parameters 3 Tap Alarm at and select the marker number from Marker 1 to Marker 6 4 Tap Ref...

Page 83: ...nna For more details see the Antenna connection below Antenna connection Before starting the measurement you need to connect the Omni or Log periodic antenna to your instrument In the Interference Finder mode and the Radar Chart mode you can perform interference hunting using the optional Antenna Advisor Handle after attaching a broadband directional antenna to it The handle is a device that has a...

Page 84: ...ator For more information on how to use the JDMapCreator see the JDMapCreator 2 0 User Guide 1 Plug in your USB flash drive that has a map file in mcf file type created in JDMapCreator 2 Tap the Load icon on the side bar 3 Navigate the map file you want to open The File Information pane displays the file properties including its name size type and date modified 4 Tap the Load button on the screen ...

Page 85: ...tion for later evaluation With this functionality you can mark locations where you have performed a measurement Thus you can analyze the geographical distribution of the received signal strength This allows you to analyze for example the coverage conditions around a base station s coverage area In the map view a point is displayed as a dot with a number The straight line represents the direction y...

Page 86: ... points in the internal memory so that you can load them by using the Load Position icon on the side panel You can save and load up to 10 positions Setting display mode When the triangulation is done with three location points and azimuth for each point you can view a circumscribed circle by default You can change the display mode to inscribed circle or double circles to view a narrower area The c...

Page 87: ...ctrum measurements See Configuring Spectrum Measurements for more details For antenna connection see antenna connection in Interference finder Loading a map To use any features related to maps you need to download and install the maps on the CellAdvisor 5G The VIAVI JDMapCreator will help you download maps Make sure the JDMapCreator application on your computer is connected to the instrument via L...

Page 88: ...he compass when you notice that the red line on the radar chart is not aligned with the north on the map even though you are pointing the antenna to the north Obtaining RSSI data Once you have connected your antenna handle set and done necessary setups you can monitor the power level of the received signal the amount of polarization and elevation level real time Using the Trigger button on the ant...

Page 89: ...tion soft key twice or performing the initialization of the AntennaAdvisor Handle Concentric circles indicate different levels of RSSI You can use the AMP SCALE hard to adjust the amplitude scale of the chart 7 Tap Setup Screen Mode Full Map to change the display mode a Map It displays measured points inside the base map image If you are in the area outside the base map and continue your measureme...

Page 90: ...p the right and left button to change the speed from the options x1 x2 x3 and x4 6 Toggle the Play button to start playing 7 Toggle the Pause button to pause or stop playing 8 Tap Fail to move to a particular failure position directly and play from there The Frame Fail Count in the middle of bar changes 9 Tap the Frame Fail Count to change the value using the on screen keyboard Once tapped replayi...

Page 91: ...on e Tap the X button to return to previous screen 3 Tap Uplink Center Frequency and input a value using the on screen keyboard 4 Tap Uplink Span and input a value using the on screen keyboard 5 Tap Channel Standard select Technology and Band and then the Apply button 6 Tap Channel Number and input a value using the on screen keyboard 7 Tap the Continue button on the right edge to continue 8 Set t...

Page 92: ...same for Radio 2 Frequency f Tap the X button to return to previous screen 3 Tap Uplink Center Frequency and input a value using the on screen keyboard 4 Tap Uplink Span and input a value using the on screen keyboard 5 Tap Channel Standard select Technology and Band and then the Apply button 6 Tap Channel Number and input a value using the on screen keyboard 7 Tap the Continue Step2 4 button on th...

Page 93: ...Hz in addition to existing 24 GHz to 40 GHz Spectrum Analysis Persistent Spectrum Persistent Spectrogram Interference Analysis Persistent RSSI Persistent Interference Finder Persistent Radar Chart Utility Real time Spectrum Replayer Selecting mode and measure To start measurement do the following steps 1 Tap Real time Spectrum Analyzer on the MODE panel 2 Tap any measurement mode from the followin...

Page 94: ...threshold for the reference line using the on screen keyboard e Optional To adjust the volume for alarm sound tap Volume and input from 1 to 10 using the on screen keyboard Setting measure setup for Interference ID The Interference ID automatically classifies interfering signals over a designated spectrum and displays the list of possible signal types corresponding to the selected signal 1 Tap the...

Page 95: ...en keyboard The dot persistence time means the time that accumulates heatmap data 3 Tap to switch Bitmap Scale to On to enable auto scale or Off to disable auto scale If the Bitmap Scale is On the point where the maximum hit represents maximum colors if the Bitmap Scale is Off the bluer color closer to 0 of the color bar is mapped with hit 4 Tap Bitmap Min and input value using the on screen keybo...

Page 96: ...trength Setting measure setup After configuring spectrum measurement in Configuring Spectrum Measurements you can set the measure setup to continue your measurement 1 Tap the Setup icon on the side bar 2 Tap Time Interval to set the amount of time between each trace measurement using the on screen keyboard 3 Tap Time Cursor to On to set the time cursor on a specific trace position The Position men...

Page 97: ... the x axis 3 Tap the chart screen to move the heatmap marker or move the vertical bar and horizontal bar NOTE If you select the heatmap marker you can only use Peak Search and Always Peak options Delta pair is not available as well See Using maker for more details Setting bitmap 1 Tap Menu Bitmap 2 Tap Dot Persistence Time and input a value using the on screen keyboard The dot persistence time me...

Page 98: ...sign power limit line for audible alarms and increase alarm counters every time a signal exceeds a defined limit line For long term analysis the spectrogram and RSSI measurements can be automatically saved into an external USB memory Setting measure setup After configuring spectrum measurement in Configuring Spectrum Measurements you can set the measure setup to continue your measurement 1 Tap the...

Page 99: ... 44 MHz 30 72 MHz 15 36 MHz 7 68 MHz 3 84 MHz Display Bandwidth 100 MHz 50 MHz 25 MHz 14 MHz 7 MHz 3 MHz RBW 100 kHz to 30 MHz 100 kHz to 10 MHz 30 kHz to 10 MHz 10 kHz to 3 MHz 10 kHz to 3 MHz 3 kHz to 1 MHz b Tap Speed and input a value using the on screen keyboard 8 Tap Reset Restart to start a new measurement NOTE You must set the marker s for the alarm as this feature use the marker position ...

Page 100: ...e of the feature available in the map mode you will need a GPS receiver and an antenna For more details see the antenna connection below Antenna connection Before starting the measurement you need to connect the Omni or Log periodic antenna to your instrument In the Interference Finder mode and the Radar Chart mode you can perform interference hunting using the optional Antenna Advisor Handle afte...

Page 101: ...er to the instrument directly by using the Send to EQP menu in JDMapCreator For more information on how to use the JDMapCreator see the JDMapCreator 2 0 User Guide 1 Plug in your USB flash drive that has a map file in mcf file type created in JDMapCreator 2 Tap the Load icon on the side bar 3 Navigate the map file you want to open The File Information pane displays the file properties including it...

Page 102: ...can evaluate the Point information directly onsite or save the information for later evaluation With this functionality you can mark locations where you have performed a measurement Thus you can analyze the geographical distribution of the received signal strength This allows you to analyze for example the coverage conditions around a base station s coverage area In the map view a point is display...

Page 103: ... with three location points and azimuth for each point you can view a circumscribed circle by default You can change the display mode to inscribed circle or double circles to view a narrower area The center of the green shaded circle is determined to be where the source of the interfering signal resides 1 Tap Measure Setup Display 2 Select the option from the following choices a Circum displays a ...

Page 104: ...ectional antenna is mandatory in the Radar Chart mode and its built in compass GPS antenna and a built in low noise amplifier LNA benefits you to determine the direction of the interference You can switch the main screen from spectrum view to map view and vice versa using the icon on the spectrum view screen Before starting the Interference Finder you need to set Spectrum measurements See Configur...

Page 105: ... yourself at the location where the value of magnetic field strength displayed on the instrument is green 2 Point the antenna to the north and tap the Setup Initialize AntennaAdvisor The message disappears and the red line for the current antenna direction moves to the 0 degree line and overlaps to let you know that the initialization is done successfully NOTE It is recommended that you re initial...

Page 106: ... chart is 2500 points both in the single and continuous measurements If your measurement reached to 500 points you need to reset the measurement by pressing the Localization soft key twice or performing the initialization of the AntennaAdvisor Handle Concentric circles indicate different levels of RSSI You can use the AMP SCALE hard to adjust the amplitude scale of the chart 7 Tap Setup Screen Mod...

Page 107: ... RBW 30 kHz to 10 MHz 10 kHz to 1 MHz 3 kHz to 1 MHz 1 kHz to 300 kHz Mode A B C D E F High POI 18 5 to 2 5 μs 29 5 to 4 μs 73 5 to 7 5 μs 147 to 15 μs 284 to 28 μs 587 to 56 5 μs Effective Bandwidth 122 88 MHz 61 44 MHz 30 72 MHz 15 36 MHz 7 68 MHz 3 84 MHz Display Bandwidth 100 MHz 50 MHz 25 MHz 14 MHz 7 MHz 3 MHz RBW 100 kHz to 30 MHz 100 kHz to 10 MHz 30 kHz to 10 MHz 10 kHz to 3 MHz 10 kHz to...

Page 108: ...and the red color indicates Fail 4 Tap the replay direction icon between FWD and REV to change play direction to forward or reverse 5 Tap the right and left button to change the speed from the options x1 x2 x3 and x4 6 Toggle the Play button to start playing 7 Toggle the Pause button to pause or stop playing 8 Tap Fail to move to a particular failure position directly and play from there The Frame...

Page 109: ...visor 5G User s Guide 97 NOTE If you connected a USB drive do not remove it while playing Doing so may freeze the USB port which will require you to restart the instrument to get a USB drive recognized again ...

Page 110: ......

Page 111: ...cedures providing service providers with accurate and reliable LTE LTE A FDD measurement results The CellAdvisor 5G is the optimal solution to perform following measurements Spectrum Analysis Spectrum RF Analysis Channel Power Occupied Bandwidth Spectrum Emission Mask ACLR Multi ACLR Spurious Emissions Power vs Time Power vs Time Frame Modulation Analysis Constellation Data Channel Control Channel...

Page 112: ...wer vs Time Frame Modulation Analysis Constellation Data Channel Control Channel Subframe Frame Time Alignment Error Data Allocation Map or Carrier Aggregation OTA Analysis OTA Channel Scanner OTA ID Scanner OTA Multipath Profile OTA Control Channel OTA Datagram OTA Route Map or Freq Time Power Variation Miscellaneous Power Statistics CCDF Conducting spectrum measurement Spectrum If you have confi...

Page 113: ...surement The measurement settings can be saved and recalled as a file by selecting File Type as Setup and load the file onto the instrument using the Save Load icons on the side bar 1 Tap the Setup icon on the side bar 2 Tap Bandwidth and select the value from the following choices 1 4 MHz 3 MHz 5MHz 10 MHz 15 MHz or 20 MHz You can also tap the rectangle with value under the chart screen and input...

Page 114: ...sing the Save Load icons on the side bar 1 Tap the Setup icon on the side bar 2 Tap Bandwidth and select the value from the following choices 1 4 MHz 3 MHz 5MHz 10 MHz 15 MHz or 20 MHz You can also tap the rectangle with value under the chart screen and input the value using the on screen keyboard 3 Tap to set the center frequency using the on screen keyboard 4 Tap Menu BW AVG Average to set the n...

Page 115: ...easurement in Configuring Spectrum Measurements you can set the measure setup to continue your measurement The measurement settings can be saved and recalled as a file by selecting File Type as Setup and load the file onto the instrument using the Save Load icons on the side bar 1 Tap the Setup icon on the side bar 2 Tap Bandwidth and select the value from the following choices 1 4 MHz 3 MHz 5MHz ...

Page 116: ...rier and the specified offset frequency band Setting measure setup After configuring spectrum measurement in Configuring Spectrum Measurements you can set the measure setup to continue your measurement The measurement settings can be saved and recalled as a file by selecting File Type as Setup and load the file onto the instrument using the Save Load icons on the side bar 1 Tap the Setup icon on t...

Page 117: ...20 MHz You can also tap the rectangle with value under the chart screen and input the value using the on screen keyboard 3 Tap Lowest Frequency to set the starting center frequency and enter the value using the on screen keyboard 4 Tap highest frequency to set the stopping center frequency and enter the value using the on screen keyboard 5 Tap Lowest Channel Number to set the starting channel and ...

Page 118: ...ns mode The measurement settings can be saved and recalled as a file by selecting File Type as Setup and load the file onto the instrument using the Save Load icons on the side bar 1 Tap the Setup icon on the side bar 2 Tap Configuration or Configuration icon 2 Tap Range under the chart screen and switch to On to display or Off to hide the selected range in the result table You can select the rang...

Page 119: ...ly shows the selected range and if you select the second icon next to the Range table it keeps moving from the first selected range to the final selected range Power vs Time Power vs Time Frame The Power vs Time Frame measures the modulation envelope in the time domain showing the power of each time slot in a LTE LTE A FDD signal Setting measure setup After configuring spectrum measurement in Conf...

Page 120: ... set the Test limits to On or Off with setting High and Low Limits using the on screen keyboard to enable or disable Pass Fail indication 3 Optional Tap the Save icon on the side bar and select the save option form the choices available for your measurement mode Power vs Time Frame measurement with LTE LTE A FDD Analyzer NOTE You can set the Subframe No from 0 to 9 based on your need using the on ...

Page 121: ...If the MIMO is set to 2x2 the antenna ports 2 and 3 are disabled c To turn the Multimedia Broadcast Multicast Service MBMS feature on or off tap MBMS and select On or Off For proper MBMS testing you need to set the Subframe Number in the upper right screen with the same PMCH subframe number If this setting is on the measurement item MBSFN RS appears in the result table d To set the Multicast Broad...

Page 122: ...umber of subframe using the on screen keyboard NOTE For MBMS testing this subframe number must be either 0 nor 5 as these subframes 0 and 5 are not available for MBMS and it must be set to the MBMS transmitted channel s subframe number 4 Optional Tap Physical Cell ID and select the type Manual or Auto Auto lets the instrument detect the Physical Cell ID for the LTE signal automatically and Manual ...

Page 123: ...manually entered MBSFN ID appears on the screen e To select the Cyclic Prefix tap Cyclic Prefix and select Normal or Extended f To set the threshold for PDSCH tap PDSCH Threshold and enter a value by using the on screen keyboard g Tap PDSCH Modulation Type and then select the modulation type option Auto QPSK 16 QAM 64 QAM 256 QAM E TM3 3 E TM3 2 E TM3 1a E TM3 1 E TM2a E TM2 E TM1 2 or E TM1 1 If ...

Page 124: ...ng the on screen keyboard NOTE For MBMS testing this subframe number must be either 0 nor 5 as these subframes 0 and 5 are not available for MBMS and it must be set to the MBMS transmitted channel s subframe number 4 Optional Tap Physical Cell ID and select the type Manual or Auto Auto lets the instrument detect the Physical Cell ID for the LTE signal automatically and Manual sets a specific Physi...

Page 125: ... RS appears in the result table d To set the Multicast Broadcast Single Frequency Network MBSFN detection automatically or manually for MBMS testing tap MBSFN and select Auto or Manual An automatically detected or manually entered MBSFN ID appears on the screen e To select the Cyclic Prefix tap Cyclic Prefix and select Normal or Extended f To set the threshold for PDCCH tap PDCCH Threshold and ent...

Page 126: ...ur CA5G series with a 2x1 or 4x1 combiner or an antenna 8 Optional Tap Miscellaneous under Menu to do the following as needed a To select the number of antenna ports tap the MIMO and select 2x2 or 4x4 b To assign a antenna port number automatically or manually tap the Antenna Port under Antenna menu and select the option Auto Antenna 0 Antenna 1 Antenna 2 or Antenna 3 If the MIMO is set to 2x2 the...

Page 127: ...o enable or disable Pass Fail indication Using marker If you turn the Chart view on you can use Marker to place a marker at a specific symbol 1 Tap Menu Marker 2 Tap Marker View between On and Off to display or dismiss the marker on the chart 3 Tap Symbol to select the symbol number to which the marker is placed Enter the value using the on screen keyboard Subframe measurement with LTE LTE A FDD A...

Page 128: ...us under Menu to do the following as needed a To select the number of antenna ports tap the MIMO and select 2x2 or 4x4 b To assign a antenna port number automatically or manually tap the Antenna Port under Antenna menu and select the option Auto Antenna 0 Antenna 1 Antenna 2 or Antenna 3 If the MIMO is set to 2x2 the antenna ports 2 and 3 are disabled c To turn the Multimedia Broadcast Multicast S...

Page 129: ... Load icons on the side bar 1 Tap the Setup icon on the side bar 2 Tap Bandwidth and select the value from the following choices 1 4 MHz 3 MHz 5MHz 10 MHz 15 MHz or 20 MHz 3 Optional Tap Physical Cell ID and select the type Manual or Auto Auto lets the instrument detect the Physical Cell ID for the LTE signal automatically and Manual sets a specific Physical Cell ID for the LTE signal manually in ...

Page 130: ...lly in order to speed up the synchronization with a BTS 5 Optional To set the threshold for PDSCH tap PDSCH Threshold and enter a value by using the on screen keyboard 6 Optional Tap Miscellaneous under Menu to do the following as needed a To select the number of antenna ports tap the MIMO and select 2x2 or 4x4 b To assign a antenna port number automatically or manually tap the Antenna Port under ...

Page 131: ... required for LTE Advanced Component carriers to be aggregated can be intra band contiguous intra band non contiguous or inter band The CA5G provides carrier aggregation measurements supporting for all the different modes with carrier aggregation bands added to the channel standard This functionality is activated if the license for the option 030 LTE Advanced FDD is installed Setting measure setup...

Page 132: ...tion Mode is set to Combine tap Subframe Number and then select 0 or 5 9 To set the threshold for PDSCH tap PDSCH Threshold and enter a value by using the on screen keyboard 10 Tap PDSCH Precoding between On and Off to enable or disable the PDSCH precoding Setting limit 1 Tap Menu Limit 2 Tap Frequency Error to set the Test limits between On and Off and set High and Low Limits using the on screen ...

Page 133: ...starting a signal processing based on the external input trigger GPS When synchronizing the signal processing via the GPS receiver If you want to check the time error correctly set the trigger to GPS Carrier setting 1 Tap Index to select up to 6 numbers of carriers 2 Tap the Center Frequency box and input the value using the on screen keyboard 3 Tap the Channel Standard box and choose one from the...

Page 134: ...Using LTE LTE A FDD Analyzer 122 OTA Channel Scanner measurement with LTE LTE A FDD Analyzer OTA Channel Scanner measurement with frequency error OTA Channel Scanner measurement with time error ...

Page 135: ...ambling code assigned to the particular base station and it differentiates its signal from other base stations in the area The ID Scanner shows key parameters such as RSRP Reference Signal Received Power and RSRQ Reference Signal Received Quality that predict the downlink coverage quickly RSRPs from entire cells help to rank between the different cells as input for handover and cell reselection de...

Page 136: ...ast signal arriving at the receiving antenna out of phase This can be caused by the signal being reflected off objects such as buildings or being refracted through the atmosphere differently from the main signal Setting measure setup After configuring spectrum measurement in Configuring Spectrum Measurements you can set the measure setup to continue your measurement The measurement settings can be...

Page 137: ...up icon on the side bar 2 Tap Bandwidth and select the value from the following choices 1 4 MHz 3 MHz 5MHz 10 MHz 15 MHz or 20 MHz 3 Tap Subframe Number to set the number of subframe using the on screen keyboard NOTE For MBMS testing this subframe number must be either 0 nor 5 as these subframes 0 and 5 are not available for MBMS and it must be set to the MBMS transmitted channel s subframe number...

Page 138: ... Datagram is a time varying spectral representation that shows how the power of a signal varies with time The power allocated to the specific resource block will be represented with an amplitude axis in dBm and the waterfall diagram will show the trend of past resource block power over certain period Using a marker function facilitates analysis of accumulated resource block power for data utilizat...

Page 139: ...cluding data of the strongest LTE signal for each measurement point including its measurement time and geographical location Loading a map To use any features related to maps you need to download and install the maps on the CellAdvisor 5G The VIAVI JDMapCreator will help you download maps Make sure the JDMapCreator application on your computer is connected to the instrument via LAN You can send a ...

Page 140: ...ting you can view all the collected points of the route without the loaded map b To collect data plot points manually in indoor layout without a GPS antenna select Position 4 Tap to switch Plot Item to RSRP RSRQ S SS SINR S SS RSSI P SS RSRP S SS RSRP S SS Ec Io or P SS SNR 5 Tap Bandwidth and select the value from the following choices 1 4 MHz 3 MHz 5MHz 10 MHz 15 MHz or 20 MHz NOTE The instrumen...

Page 141: ... two different color indicators red and blue The maximum value is the Limit for Excellent and the minimum value is the Limit for Poor See below to check the plot point color based on the Legend Color Table 1 Tap the rectangle with value before color legend bar on the right panel 2 Set a value for Poor minimum value using the on screen keyboard 3 Tap the rectangle with value after color legend bar ...

Page 142: ...t key on the side bar 7 Import the saved file Once the file is loaded the following cellsite information appears with an icon Route map measurement with site information screen NOTE The purple icon indicates the base station site location and the direction of antenna If the site is beyond the latitude and longitude of the map file it will not show OTA Route Map measurement with LTE LTE A FDD Analy...

Page 143: ...ally in order to speed up the synchronization with a BTS 5 Tap to switch PCI Physical Cell ID to Manual or Auto 6 Optional Tap CFI and select the type Manual or Auto Auto lets the instrument set the number of OFDM symbols used for transmitting PDCCHs in a subframe Manual sets the number of OFDM symbols manually The set of OFDM symbols that can be used for PDCCH in a subframe is given by 0 2 3 or 4...

Page 144: ... NOTE You can tap the Distance box and input the value that you want to compensate for distance When distance is entered the time will show the value with distance correction Make sure the default value for Distance is 0 Frequency time power variation by power with LTE LTE A FDD Analyzer Miscellaneous ...

Page 145: ... Setting measure setup After configuring spectrum measurement in Configuring Spectrum Measurements you can set the measure setup to continue your measurement The measurement settings can be saved and recalled as a file by selecting File Type as Setup and load the file onto the instrument using the Save Load icons on the side bar 1 Tap the Setup icon on the side bar 2 Tap CCDF Length and select the...

Page 146: ......

Page 147: ...s providing service providers with accurate and reliable LTE LTE A TDD measurement results The CellAdvisor 5G is the optimal solution to perform following measurements Spectrum Analysis Spectrum RF Analysis Channel Power Occupied Bandwidth Spectrum Emission Mask ACLR Multi ACLR Spurious Emissions Power vs Time Power vs Time Frame Power vs Time Slot Modulation Analysis Constellation Data Channel Co...

Page 148: ...e Slot Modulation Analysis Constellation Data Channel Control Channel Subframe Time Alignment Error Data Allocation Map or Carrier Aggregation OTA Analysis OTA Channel Scanner OTA ID Scanner OTA Multipath Profile OTA Control Channel OTA Datagram OTA Route Map or Freq Time Power Variation Miscellaneous Power Statistics CCDF Conducting Spectrum Measurement Spectrum If you have configured test parame...

Page 149: ...settings can be saved and recalled as a file by selecting File Type as Setup and load the file onto the instrument using the Save Load icons on the side bar 1 Tap the Setup icon on the side bar 2 Tap Bandwidth and select the value from the following choices 1 4 MHz 3 MHz 5MHz 10 MHz 15 MHz or 20 MHz You can also tap the rectangle with value under the chart screen and input the value using the on s...

Page 150: ...sing the Save Load icons on the side bar 1 Tap the Setup icon on the side bar 2 Tap Bandwidth and select the value from the following choices 1 4 MHz 3 MHz 5MHz 10 MHz 15 MHz or 20 MHz You can also tap the rectangle with value under the chart screen and input the value using the on screen keyboard 3 Tap to set the center frequency using the on screen keyboard 4 Tap Menu BW AVG Average to set the n...

Page 151: ...g File Type as Setup and load the file onto the instrument using the Save Load icons on the side bar 1 Tap the Setup icon on the side bar 2 Tap Bandwidth and select the value from the following choices 1 4 MHz 3 MHz 5MHz 10 MHz 15 MHz or 20 MHz You can also tap the rectangle with value under the chart screen and input the value using the on screen keyboard 3 Tap Mask Type and select the type from ...

Page 152: ...tinue your measurement The measurement settings can be saved and recalled as a file by selecting File Type as Setup and load the file onto the instrument using the Save Load icons on the side bar 1 Tap the Setup icon on the side bar 2 Tap Bandwidth and select the value from the following choices 1 4 MHz 3 MHz 5MHz 10 MHz 15 MHz or 20 MHz You can also tap the rectangle with value under the chart sc...

Page 153: ...20 MHz You can also tap the rectangle with value under the chart screen and input the value using the on screen keyboard 3 Tap Lowest Frequency to set the starting center frequency and enter the value using the on screen keyboard 4 Tap highest frequency to set the stopping center frequency and enter the value using the on screen keyboard 5 Tap Lowest Channel Number to set the starting channel and ...

Page 154: ...s a file by selecting File Type as Setup and load the file onto the instrument using the Save Load icons on the side bar 1 Tap the Setup icon on the side bar 2 Tap Configuration or Configuration icon 2 Tap Range under the chart screen and switch to On to display or Off to hide the selected range in the result table You can select the range number between 1 and 20 to add as a new or change the exis...

Page 155: ...wing the power of each time slot in a LTE LTE A TDD signal Setting measure setup After configuring spectrum measurement in Configuring Spectrum Measurements you can set the measure setup to continue your measurement The measurement settings can be saved and recalled as a file by selecting File Type as Setup and load the file onto the instrument using the Save Load icons on the side bar 1 Tap the S...

Page 156: ...TDD Analyzer Power vs Time Slot The Power vs Time Slot in LTE LTE A TDD Signal Analyzer measures the modulation envelope in the time domain showing the signal rise and fall shapes of LTE LTE A TDD signal NOTE In this measurement desirable level of the input power is lower than 10 dBm If the input power to be measured is 10 dBm or higher it is highly recommended that you use an external attenuator ...

Page 157: ... Off with setting High and Low Limits using the on screen keyboard to enable or disable Pass Fail indication 3 Optional Tap the Save icon on the side bar and select the save option form the choices available for your measurement mode Power vs Time Slot measurement with LTE LTE A TDD Analyzer Modulation Analysis Constellation The Constellation is used to observe some aspects of modulation accuracy ...

Page 158: ...ature on or off tap MBMS and select On or Off For proper MBMS testing you need to set the Subframe Number in the upper right screen with the same PMCH subframe number If this setting is on the measurement item MBSFN RS appears in the result table d To set the Multicast Broadcast Single Frequency Network MBSFN detection automatically or manually for MBMS testing tap MBSFN and select Auto or Manual ...

Page 159: ...or 5 as these subframes 0 and 5 are not available for MBMS and it must be set to the MBMS transmitted channel s subframe number 4 Optional Tap Physical Cell ID and select the type Manual or Auto Auto lets the instrument detect the Physical Cell ID for the LTE signal automatically and Manual sets a specific Physical Cell ID for the LTE signal manually in order to speed up the synchronization with a...

Page 160: ...he on screen keyboard to set the amount of delay in μs NOTE The Delay setting is used only when there is a time offset in the signals to be measured f To select the Cyclic Prefix tap Cyclic Prefix and select Normal or Extended g To set the threshold for PDSCH tap PDSCH Threshold and enter a value by using the on screen keyboard h Tap PDSCH Modulation Type and then select the modulation type option...

Page 161: ...these subframes 0 and 5 are not available for MBMS and it must be set to the MBMS transmitted channel s subframe number 4 Optional Tap Physical Cell ID and select the type Manual or Auto Auto lets the instrument detect the Physical Cell ID for the LTE signal automatically and Manual sets a specific Physical Cell ID for the LTE signal manually in order to speed up the synchronization with a BTS 5 O...

Page 162: ...ng tap MBSFN and select Auto or Manual An automatically detected or manually entered MBSFN ID appears on the screen e To set the delay tap Delay and enter the value using the on screen keyboard to set the amount of delay in μs NOTE The Delay setting is used only when there is a time offset in the signals to be measured f To select the Cyclic Prefix tap Cyclic Prefix and select Normal or Extended g...

Page 163: ...series with a 2x1 or 4x1 combiner or an antenna 8 Tap Uplink Downlink Config and select the number of uplink downlink from one to six using the on screen keyboard 9 Optional Tap Miscellaneous under Menu to do the following as needed a To select the number of antenna ports tap the MIMO and select 2x2 or 4x4 b To assign a antenna port number automatically or manually tap the Antenna Port under Anten...

Page 164: ...enable or disable Pass Fail indication Using marker If you turn the Chart view on you can use Marker to place a marker at a specific symbol 1 Tap Menu Marker 2 Tap Marker View between On and Off to display or dismiss the marker on the chart 3 Tap Symbol to select the symbol number to which the marker is placed Enter the value using the on screen keyboard Subframe measurement with LTE LTE A TDD Ana...

Page 165: ... Optional To select the number of antenna ports tap the MIMO and select 2x2 or 4x4 5 Optional To assign an antenna port number automatically or manually tap the Antenna Port under Antenna menu and select the option Auto Antenna 0 Antenna 1 Antenna 2 or Antenna 3 If the MIMO is set to 2x2 the antenna ports 2 and 3 are disabled 6 To set the delay tap Delay and enter the value using the on screen key...

Page 166: ...d a To select the number of antenna ports tap the MIMO and select 2x2 or 4x4 b To assign a antenna port number automatically or manually tap the Antenna Port under Antenna menu and select the option Auto Antenna 0 Antenna 1 Antenna 2 or Antenna 3 If the MIMO is set to 2x2 the antenna ports 2 and 3 are disabled c To turn the Multimedia Broadcast Multicast Service MBMS feature on or off tap MBMS and...

Page 167: ...mponent carrier configuration window appears 3 Select the number of the component carrier to be set between one and five by tapping the number in Range box 4 Set the Range On to set parameters and view the results for the selected component carrier on the screen or Off to turn it off 5 Tap LAA License Assisted Access and select one among the three options 2 4 GHz 5 GHz or Off 6 Set the following p...

Page 168: ...oard for each Intra Cont High Intra Non Cont High and Inter Band High to enable or disable Pass Fail indication Carrier Aggregation measurement with LTE LTE A TDD Analyzer OTA Analysis Channel Scanner The Channel Scanner is a radio receiver that can automatically tune or scan two or more discrete frequencies and multi channels indicating when it finds a signal on one of them and then continuing sc...

Page 169: ...Tap the Channel Number box and input the value using the on screen keyboard 5 Tap the Bandwidth box and select from 1 4 MHz 3 MHz 5MHz 10 MHz 15 MHz or 20 MHz 6 Tap the External Offset box and input the value using the on screen keyboard and tap to switch the external offset to On green or Off gray as desired 7 Tap the Attenuation box and input the value using the on screen keyboard if you want to...

Page 170: ...Using LTE LTE A TDD Analyzer 158 OTA Channel Scanner measurement with LTE LTE A TDD Analyzer OTA Channel Scanner measurement with frequency error OTA Channel Scanner measurement with time error ...

Page 171: ...es its signal from other base stations in the area The ID Scanner shows key parameters such as RSRP Reference Signal Received Power and RSRQ Reference Signal Received Quality that predict the downlink coverage quickly RSRPs from entire cells help to rank between the different cells as input for handover and cell reselection decisions RSRQ provides additional information when RSRP is not sufficient...

Page 172: ...racted through the atmosphere differently from the main signal Setting measure setup After configuring spectrum measurement in Configuring Spectrum Measurements you can set the measure setup to continue your measurement The measurement settings can be saved and recalled as a file by selecting File Type as Setup and load the file onto the instrument the Save Load icons on the side bar 1 Tap the Set...

Page 173: ... on screen keyboard NOTE For MBMS testing this subframe number must be either 0 nor 5 as these subframes 0 and 5 are not available for MBMS and it must be set to the MBMS transmitted channel s subframe number 4 Optional Tap Physical Cell ID and select the type Manual or Auto Auto lets the instrument detect the Physical Cell ID for the LTE signal automatically and Manual sets a specific Physical Ce...

Page 174: ... the waterfall diagram will show the trend of past resource block power over certain period Using a marker function facilitates analysis of accumulated resource block power for data utilization Setting measure setup After configuring spectrum measurement in Configuring Spectrum Measurements you can set the measure setup to continue your measurement The measurement settings can be saved and recalle...

Page 175: ...ime and geographical location Loading a map To use any features related to maps you need to download and install the maps on the CellAdvisor 5G The VIAVI JDMapCreator will help you download maps Make sure the JDMapCreator application on your computer is connected to the instrument via LAN You can send a map file with a single layer to the instrument directly by using the Send to EQP menu in JDMapC...

Page 176: ... be seen within the boundary of the loaded map With the Full setting you can view all the collected points of the route without the loaded map b To collect data plot points manually in indoor layout without a GPS antenna select Position 4 Tap to switch Plot Item to RSRP RSRQ S SS SINR S SS RSSI P SS RSRP S SS RSRP S SS Ec Io or P SS SNR 5 Tap Bandwidth and select the value from the following choic...

Page 177: ... all the loaded data the screen mode will be automatically changed to Full Setting limit You can set the thresholds for the two different color indicators red and blue The maximum value in red is the Limit for Excellent and the minimum value in blue is the Limit for Poor See below to check the plot point color based on the Legend Color Table 1 Tap the rectangle with value before color legend bar o...

Page 178: ...USB memory stick and insert it to the USB A or USB B port of the instrument 6 Tap the Load hot key on the side bar 7 Import the saved file Once the file is loaded the following cellsite information appears with an icon Route map measurement with site information screen NOTE The purple icon indicates the base station site location and the direction of antenna If the site is beyond the latitude and ...

Page 179: ... lets the instrument detect the Physical Cell ID for the LTE signal automatically Manual sets the specific Physical Cell ID for the LTE signal manually in order to speed up the synchronization with a BTS 4 Tap to switch PCI Physical Cell ID to Manual or Auto 5 Optional Tap CFI and select the type Manual or Auto Auto lets the instrument set the number of OFDM symbols used for transmitting PDCCHs in...

Page 180: ... Time Error Reference Level and Scale Division Power on demand using the on screen keyboard You can also select the unit on the keyboard Frequency time power variation by offset with LTE LTE A TDD Analyzer NOTE You can tap the Distance box and input the value that you want to compensate for distance When distance is entered the time will show the value with distance correction Make sure the defaul...

Page 181: ...s PAR Peak to Average power Ratio versus different probabilities Setting measure setup After configuring spectrum measurement in Configuring Spectrum Measurements you can set the measure setup to continue your measurement The measurement settings can be saved and recalled as a file by selecting File Type as Setup and load the file onto the instrument using the Save Load icons on the side bar 1 Tap...

Page 182: ...Using LTE LTE A TDD Analyzer 170 CCDF measurement with LTE LTE A TDD Analyzer ...

Page 183: ...hannel scanner Before starting the Channel Scanner you need to set Spectrum measurements displayed on the quick access and display tab See Configuring Spectrum Measurements for more details Setting measure setup You need to set the channel to be scanned 1 Tap the Menu icon on the side bar and tap Channel Channel menus appears 2 Tap Channel Standard to select the standard channel The channel standa...

Page 184: ... details Setting measure setup You need to set the frequency to be scanned 1 Tap the Menu icon on the side bar and tap Frequency Frequency menus appears 2 Tap Start Frequency to set the starting center frequency using the on screen keyboard 3 Tap Frequency Step to set the amount of frequency increment in scanning channel using the on screen keyboard 4 Tap Integration BW and input a value using the...

Page 185: ...Configuration or Tap the Edit icon on the result table Setup table appears as below 3 Tap Channel Standard to select the channel standard The channel standard window appears 4 Select Technology and then the band to be measured by tapping 5 Tap the Apply button to apply the settings 6 Tap to switch the Link to uplink or downlink 7 Tap Index and select the number from 1 to 20 8 Tap Channel No to set...

Page 186: ...e button to Add to add more channels to be scanned and repeat steps 1 3 5 Tap the X button to dismiss the channel list window and view the scanning result Custom scanner measurement Test results can be saved as a csv file format so that you can work on it in any spreadsheet software NOTE You can go to Menu Limit to analyze your measurements with the limit line using the on screen keyboard and the ...

Page 187: ...surement of the beam through the entire transmission bandwidth 90 MHz P SS RSSI Primary Synchronization Signal Received Signal Strength Indicator average power measurement through all the primary sync signals BRS SNR Beam Reference Signal Signal to Noise Ratio is the ratio between the average power of the beam reference signals through the transmission bandwidth 90MHz and average noise level of th...

Page 188: ...ll be indicated as You cannot save the measurement as a Result Logging as CSV option is added For more details see Managing files Carrier scanner 5G Carrier Scanner provides an easy and fast response power measurements of up to eight single component carriers of 100 MHz The power measurement for each carrier includes A Channel Power integrated power of the entire channel bandwidth 100MHz during an...

Page 189: ...ghlighted purple 6 Tap X button to close the center frequency setup table 7 Tap the Search icon of the selected carrier in the carrier scanner table to set the limit This enables you to check the beam information without changing the measurement mode to Beam Analyzer The beam information pops up for the selected carrier a Select the Limit icon to set BRSRP Line and BRS SNR Line to On or Off When s...

Page 190: ... Make sure the JDMapCreator application on your computer is connected to the instrument via LAN You can send a map file with a single layer to the instrument directly by using the Send to EQP menu in JDMapCreator For more information on how to use the JDMapCreator see the JDMapCreator 2 0 User Guide 1 Plug in your USB flash drive that has a map file in mcf file type created in JDMapCreator 2 Tap t...

Page 191: ...the options from 5 ms 5 ms 10 ms 20 ms or Auto Set the BRS transmission period as the following 1 slot 5 ms 1 subframe 5 ms 2 subframes 10 ms 4 subframes 20 ms If you set it to Auto the CellAdvisor 5G automatically decodes MIB 6 Tap Beam Index and select between symbol order and subframe region You can select symbol order if you want to allocate the beam index in a sequential symbol order in the s...

Page 192: ...5 Tap the Apply button The point color of the map changes to the corresponding BRSRP value and if there is no detected Beam Index the point will be hidden Setting limit You can set the thresholds for the two different color indicators The maximum value is the Limit for Excellent and the minimum value is the Limit for Poor See below to check the plot point color based on the Legend Color Table 1 Ta...

Page 193: ...r USB B port of the instrument 6 Tap the Load hot key on the side bar 7 Import the saved file Once the file is loaded the following cellsite information appears with an icon Route map measurement with site information screen NOTE The purple icon indicates the base station site location and the direction of antenna If the site is beyond the latitude and longitude of the map file it will not show Ro...

Page 194: ...up to eight single component carriers power as well as the strongest beam and its power level The beam analyzer is assessing individual beam s ID power level and signal to noise levels and coverage verification including real time coverage map as well as data available for post processing Spectrum Analysis Trigger Spectrum RF Analysis Channel Power Occupied Bandwidth Spectrum Emission Mask ACLR Mu...

Page 195: ...surement in Configuring Spectrum Measurements you can set the measure setup to continue your measurement The measurement settings can be saved and recalled as a file by selecting File Type as Setup and load the file onto the instrument using the Save Load icons on the side bar 1 Tap the Setup icon on the side bar 2 Tap Bandwidth SSB SCS and select the Setting in the pop up window based on your nee...

Page 196: ... 4 8 and 64 Refer to the selection criteria based on the table in Step 2 7 Tap SSB Auto Search Mode and do the following steps a Tap Auto Preamp Atten and switch SSB Auto Search to Start to set preamp and attenuation automatically b Tap Manual and switch SSB Auto Search to Start for manually setting based on your need NOTE If you tap SSB Auto Search to Start the searching progress screen appears t...

Page 197: ... bandwidth Setting measure setup After configuring spectrum measurement in Configuring Spectrum Measurements you can set the measure setup to continue your measurement The measurement settings can be saved and recalled as a file by selecting File Type as Setup and load the file onto the instrument using the Save Load icons on the side bar 1 Tap the Setup icon on the side bar 2 Tap Bandwidth SSB SC...

Page 198: ...put the value using the on screen keyboard Based on the GSCN input frequency the SSB frequency changes automatically 6 Tap L to set the maximum number of SS PBCH blocks within a single SS burst set A set of SS being transmitted in 5 ms window of SS transmission among 4 8 and 64 Refer to the selection criteria based on the table in Step 2 7 Tap SSB Auto Search Mode and do the following steps a Tap ...

Page 199: ...ted in terms of decibels over a reference power emitted by an isotropic radiator with equivalent signal strength The EIRP allows comparisons between different emitters regardless of type size or form From the EIRP and with knowledge of a real antenna s gain it is possible to calculate real power and field strength values Formula to calculate EIRP Tx RF Power dBm GA dB FL dB Tx RF Power refers to R...

Page 200: ...urement The measurement settings can be saved and recalled as a file by selecting File Type as Setup and load the file onto the instrument using the Save Load icons on the side bar 1 Tap the Setup icon on the side bar 2 Tap Bandwidth SSB SCS and select the Setting in the pop up window based on your need SSB is abbreviation for Synchronization Signal Block or SS Block and it actually refers to Sync...

Page 201: ...maximum number of SS PBCH blocks within a single SS burst set A set of SS being transmitted in 5 ms window of SS transmission among 4 8 and 64 Refer to the selection criteria based on the table in Step 2 7 Tap SSB Auto Search Mode and do the following steps a Tap Auto Preamp Atten and switch SSB Auto Search to Start to set preamp and attenuation automatically b Tap Manual and switch SSB Auto Searc...

Page 202: ...width and modulated signal It measures the power ratio between in band and adjacent channels The CellAdvisor 5G indicates either Pass or Fail based on the specified limit of the signal Setting measure setup After configuring spectrum measurement in Configuring Spectrum Measurements you can set the measure setup to continue your measurement The measurement settings can be saved and recalled as a fi...

Page 203: ...put the value using the on screen keyboard Based on the GSCN input frequency the SSB frequency changes automatically 6 Tap L to set the maximum number of SS PBCH blocks within a single SS burst set A set of SS being transmitted in 5 ms window of SS transmission among 4 8 and 64 Refer to the selection criteria based on the table in Step 2 7 Tap SSB Auto Search Mode and do the following steps a Tap ...

Page 204: ...een keyboard The input value range is from 1 to 100 Setting limit 1 Tap Menu Limit 2 Tap to switch the Test Limits to On or Off to enable or disable Pass Fail indication The result table color for Pass is green and the result table color for Fail is red 3 Optional Tap the Save hot key on the side bar and select the save option form the choices available for your measurement mode Spectrum emission ...

Page 205: ... FR2 64 D 4 8 16 20 28 n 120 kHz 40 0 125 ms E 8 12 16 20 32 36 40 44 56 n 240 kHz 80 62 5 ms 3 Tap Sync Raster SCS Offset to set the sync raster resolution to 180 kHz FR1 or to 720 kHz FR2 for carrier frequency center using the on screen keyboard The following table shows the sync raster offset range and sync SCS offset range per SSB SCS and sync raster SCS resolution SSB SCS kHz Sync Raster Reso...

Page 206: ...Manual 12 Tap BS Type and select the option from 1 C 1 H 1 O or 2 O Set 1 C Conducted 1 H Hybrid for multi band operation with mapping of transceivers to one or more antenna connectors 1 C or TAB transceiver array boundary connectors for 1 H Set 1 O when BS operates at FR1 and 2 0 when BS operates at FR2 13 Tap Category and select the option from Wide Area BS A Wide Area BS B Medium Range BS or Lo...

Page 207: ...annel are packed as a single block that always moves together SSB should be detected first in 5G NR frame The following table shows the setting criteria based on the operating frequency Operating Frequency Case SCS 3 GHz FR1 A 2 8 14 n 15 kHz B 4 8 16 20 28 n 30 kHz C 2 8 14 n 30 kHz 3 to 6 GHz FR1 A 2 8 14 n 15 kHz B 4 8 16 20 28 n 30 kHz C 2 8 14 n 30 kHz 6 GHz FR2 D 4 8 16 20 28 n 120 kHz E 8 1...

Page 208: ...m 1 C 1 H 1 O or 2 O Set 1 C Conducted 1 H Hybrid for multi band operation with mapping of transceivers to one or more antenna connectors 1 C or TAB transceiver array boundary connectors for 1 H Set 1 O when BS operates at FR1 and 2 0 when BS operates at FR2 3 Tap Measure Type and select the option from Transmitted or Receiver 4 Tap to switch Setting to User if you want user defined setting and ta...

Page 209: ...ext to the Range table it keeps moving from the first selected range to the final selected range Conducting OTA measurement Beam analyzer 5G NR provides the beamforming profile of each transmission carrier including the eight strongest beams and the corresponding power levels during its transmission period and includes S SS RSRP Synchronized Signal Reference Signal Received Power linear average ov...

Page 210: ...sed on the operating frequency Operating Frequency L Case SCS Slots in a burst period slot duration 3 GHz FR1 4 A 2 8 14 n 15 kHz 5 1 ms B 4 8 16 20 28 n 30 kHz 10 0 5 ms C 2 8 14 n 30 kHz 10 0 5 ms 3 to 6 GHz FR1 8 A 2 8 14 n 15 kHz 5 1 ms B 4 8 16 20 28 n 30 kHz 10 0 5 ms C 2 8 14 n 30 kHz 10 0 5 ms 6 GHz FR2 64 D 4 8 16 20 28 n 120 kHz 40 0 125 ms E 8 12 16 20 32 36 40 44 56 n 240 kHz 80 62 5 m...

Page 211: ... the status of searching You can tap SSB Auto Search to Stop to stop searching 8 Tap SSB Periodicity and select the options from 5 ms 10 ms 20 ms 40 ms 80 ms 160 ms The SS burst period SSB periodicity is defined by each base station and network configurable 20 ms is the default for the initial cell selection 9 Tap to switch PCI Physical Cell ID to Manual or Auto 10 Tap PCI and input a value from 0...

Page 212: ...tup icon Configuration on the side bar a Tap the number to switch the carrier on or off in the Carrier Configuration box You can select up to 8 carriers b Tap the Center Frequency box and input the value using the on screen keyboard c Tap the Channel Standard box and choose one from the pop up window and tap the Apply button d Tap the Channel Number box and input the value using the on screen keyb...

Page 213: ...d on the base station Once the Start button is tapped the progress bar appears o Tap Sync SCS Offset and input the required value using the on screen keyboard p Tap Distance and input the required value using the on screen keyboard This will be applied when you are measuring the frequency and time error Viewing beam information 1 Tap the Search icon of the selected carrier highlighted in purple in...

Page 214: ...ignal Analyzer 202 Setting the sweep speed 1 Tap Menu Sweep 2 Tap Sweep Speed and you can choose between Fast and Normal Carrier scanner measurement NOTE You cannot save the measurement as a Result or Result as CSV ...

Page 215: ...ing icons You can tap the Magnifier icon to check the frequency or time error You can also perform the following operation using the icons Auto scale You can set the scale automatically Save as CSV You can assign file name using the on screen keyboard and apply the changes This will let you save your measurement file internally ...

Page 216: ...er is connected to the instrument via LAN You can send a map file with a single layer to the instrument directly by using the Send to EQP menu in JDMapCreator For more information on how to use the JDMapCreator see the JDMapCreator 1 9 User Guide 1 Plug in your USB flash drive that has a map file in mcf file type created in JDMapCreator 2 Tap the Load icon on the side bar 3 Navigate the map file y...

Page 217: ...anel of the map the Undo icon appears 4 Tap to switch Plot Item to S SS RSRP P SS RSRP S SS RSRQ or S SS SINR 5 Tap Bandwidth SSB SCS and select the Setting in the pop up window based on your need SSB is abbreviation for Synchronization Signal Block or SS Block and it actually refers to Synchronization PBCH block since the synchronization signal and PBCH channel are packed as a single block that a...

Page 218: ...w the status of searching You can tap SSB Auto Search to Stop to stop searching 11 Tap SSB Periodicity and select the options from 5 ms 10 ms 20 ms 40 ms 80 ms 160 ms The SS burst period SSB periodicity is defined by each base station and network configurable 20 ms is the default for the initial cell selection 12 Tap to switch PCI Physical Cell ID to Manual or Auto 13 Tap PCI and input a value fro...

Page 219: ...E When you load the result file a pop up message asking whether you want to load data only or data with map appears If the current screen does not display all the loaded data the screen mode will be automatically changed to Full Setting limit You can set the thresholds for the two different color indicators The maximum value is the Limit for Excellent and the minimum value is the Limit for Poor Se...

Page 220: ...SB memory stick and insert it to the USB A or USB B port of the instrument 6 Tap the Load hot key on the side bar 7 Import the saved file Once the file is loaded the following cellsite information appears with an icon Route map measurement with site information screen NOTE The purple icon indicates the base station site location and the direction of antenna If the site is beyond the latitude and l...

Page 221: ...I colors in small circle and Beam power in line are displayed Route map measurement screen Plot Point to Time with 5G NR Signal Analyzer NOTE When you setup Plot Point to Time and tap the start testing button you cannot touch the screen to active After the waiting indicator stops the active indicator shows up ...

Page 222: ...ynchronization signal and PBCH channel are packed as a single block that always moves together SSB should be detected first in 5G NR frame The following table shows the setting criteria based on the operating frequency Operating Frequency L Case SCS Slots in a burst period slot duration 3 GHz FR1 4 A 2 8 14 n 15 kHz 5 1 ms B 4 8 16 20 28 n 30 kHz 10 0 5 ms C 2 8 14 n 30 kHz 10 0 5 ms 3 to 6 GHz FR...

Page 223: ... Physical Cell ID to Manual or Auto 10 Tap PCI and input a value from 0 to 1007 using the on screen keyboard The PCI switches to Manual 11 Tap Distance and input a value using the on screen keyboard 12 Tap Antenna Gain and input a value using the on screen keyboard NOTE Distance and Antenna gain values are required when calculating EIRP Effective Isotropic Radiated Power EIRP refers to the amount ...

Page 224: ...See Configuring Spectrum Measurements for more details 1 Tap the Setup icon on the side bar 2 Tap Bandwidth SSB SCS and select the Setting in the pop up window based on your need SSB is abbreviation for Synchronization Signal Block or SS Block and it actually refers to Synchronization PBCH block since the synchronization signal and PBCH channel are packed as a single block that always moves togeth...

Page 225: ...ut frequency the SSB frequency changes automatically 6 Tap L to set the maximum number of SS PBCH blocks within a single SS burst set A set of SS being transmitted in 5 ms window of SS transmission among 4 8 and 64 Refer to the selection criteria based on the table in Step 2 7 Tap SSB Auto Search Mode and do the following steps a Tap Auto Preamp Atten and switch SSB Auto Search to Start to set pre...

Page 226: ... Distance box and input the value that you want to compensate for distance When distance is entered the time will show the value with distance correction Make sure the default value for Distance is 0 Frequency time power variation by power with 5G NR Signal Analyzer Multi path profile 1 Tap the Setup icon on the side bar ...

Page 227: ...36 40 44 56 n 240 kHz 80 62 5 ms 3 Tap Sync Raster SCS Offset to set the sync raster resolution to 180 kHz FR1 or to 720 kHz FR2 for carrier frequency center using the on screen keyboard The following table shows the sync raster offset range and sync SCS offset range per SSB SCS and sync raster SCS resolution SSB SCS kHz Sync Raster Resolution kHz Sync Raster Offset Range Sync SCS Resolution kHz S...

Page 228: ...ulation measurement Constellation The Constellation is used to observe some aspects of modulation accuracy and can reveal certain fault mechanisms such as I Q amplitude imbalance or quadrature imbalance It displays constellation diagram by modulation types Setting measure setup After configuring spectrum measurement in Configuring Spectrum Measurements you can set the measure setup to continue you...

Page 229: ... SCS kHz Sync Raster Resolution kHz Sync Raster Offset Range Sync SCS Resolution kHz Sync SCS Offset Range 15 180 0 to 250 15 0 to 11 30 180 0 to 506 30 0 to 5 120 720 0 to 92 120 0 to 5 240 720 0 to 48 240 0 to 2 4 Tap SSB Frequency and input the value using the on screen keyboard 5 Tap GSCN and input the value using the on screen keyboard Based on the GSCN input frequency the SSB frequency chang...

Page 230: ...st limits On Off High Limit Low Limit SS RSRP Power SS RSRP Power Test limits On Off High Limit Low Limit PDSCH error vector magnitude PDSCH EVM Test limits On Off High Limit QPSK High Limit 16QAM High Limit 64QAM High Limit 256QAM RMS for data error vector magnitude Data EVM RMS Test limits On Off High Limit Peak for data error vector magnitude Data EVM Peak Test limits On Off High Limit 3 Option...

Page 231: ...asurements the 0 dB reference is determined by measuring the mean transmitted power during the useful part of the burst Setting measure setup After configuring spectrum measurement in Configuring Spectrum Measurements you can set the measure setup to continue your measurement The measurement settings can be saved and recalled as a file 1 Tap the Setup icon on the side bar 2 Tap Bandwidth SSB SCS a...

Page 232: ... Sync Raster Offset Range Sync SCS Resolution kHz Sync SCS Offset Range 15 180 0 to 250 15 0 to 11 30 180 0 to 506 30 0 to 5 120 720 0 to 92 120 0 to 5 240 720 0 to 48 240 0 to 2 4 Tap SSB Frequency and input the value using the on screen keyboard 5 Tap GSCN and input the value using the on screen keyboard Based on the GSCN input frequency the SSB frequency changes automatically 6 Tap L to set the...

Page 233: ... ID to Manual or Auto 10 Tap PCI and input a value from 0 to 1007 using the on screen keyboard The PCI switches to Manual 11 Tap Slot Formats and input the value from 0 to 55 using the on screen keyboard The slot format means how to use one slot between downlink and uplink Power vs Time Slot measurement with 5G NR NOTE You can set the Slot No from 0 to 19 in the Symbol Average Power table NOTE You...

Page 234: ... criteria based on the operating frequency Operating Frequency L Case SCS Slots in a burst period slot duration 3 GHz FR1 4 A 2 8 14 n 15 kHz 5 1 ms B 4 8 16 20 28 n 30 kHz 10 0 5 ms C 2 8 14 n 30 kHz 10 0 5 ms 3 to 6 GHz FR1 8 A 2 8 14 n 15 kHz 5 1 ms B 4 8 16 20 28 n 30 kHz 10 0 5 ms C 2 8 14 n 30 kHz 10 0 5 ms 6 GHz FR2 64 D 4 8 16 20 28 n 120 kHz 40 0 125 ms E 8 12 16 20 32 36 40 44 56 n 240 k...

Page 235: ...ess screen appears to let you know the status of searching You can tap SSB Auto Search to Stop to stop searching 8 Tap SSB Periodicity and select the options from 5 ms 10 ms 20 ms 40 ms 80 ms 160 ms The SS burst period SSB periodicity is defined by each base station and network configurable 20 ms is the default for the initial cell selection 9 Tap to switch PCI Physical Cell ID to Manual or Auto 1...

Page 236: ...nization signal and PBCH channel are packed as a single block that always moves together SSB should be detected first in 5G NR frame The following table shows the setting criteria based on the operating frequency Operating Frequency L Case SCS Slots in a burst period slot duration 3 GHz FR1 4 A 2 8 14 n 15 kHz 5 1 ms B 4 8 16 20 28 n 30 kHz 10 0 5 ms C 2 8 14 n 30 kHz 10 0 5 ms 3 to 6 GHz FR1 8 A ...

Page 237: ...station and network configurable 20 ms is the default for the initial cell selection 9 Tap to switch PCI Physical Cell ID to Manual or Auto 10 Tap PCI and input a value from 0 to 1007 using the on screen keyboard The PCI switches to Manual 11 Tap Symbol Phase Comp and select from the following choices Auto Manual or Off Symbol Phase Compensation is used to compensate for phase differences between ...

Page 238: ...tart always at the first symbols of scheduled SLIV Select between Configuration Type 1 and 2 In Configuration type 1 the minimum resource element group in frequency domain is one RE In Configuration type 2 the minimum resource element group in frequency domain is two consecutive REs Select DM RS Type A Position between pos2 and pos3 to set the PDSCH DM RS position for mapping type A Select DM RS A...

Page 239: ...h Limit Low Limit Channel Power Channel Power Test limits On Off High Limit Low Limit PDSCH error vector magnitude PDSCH EVM Test limits On Off High Limit QPSK High Limit 16QAM High Limit 64QAM High Limit 256QAM RMS for data error vector magnitude Data EVM RMS Test limits On Off High Limit Peak for data error vector magnitude Data EVM Peak Test limits On Off High Limit 3 Optional Tap the Save icon...

Page 240: ...summary NOTE You can tap the Enlarge icon on the top right side of the screen to zoom in the PDSCH Preview screen EVM vs Subcarrier CellAdivisor 5G NR EVM vs Subcarrier provides bar chart consisting of the average for resource elements with assigned PDSCH in each RB 12 subcarriers x 14 symbols ...

Page 241: ... 10 0 5 ms 3 to 6 GHz FR1 8 A 2 8 14 n 15 kHz 5 1 ms B 4 8 16 20 28 n 30 kHz 10 0 5 ms C 2 8 14 n 30 kHz 10 0 5 ms 6 GHz FR2 64 D 4 8 16 20 28 n 120 kHz 40 0 125 ms E 8 12 16 20 32 36 40 44 56 n 240 kHz 80 62 5 ms 3 Tap SSB Frequency to set SSB location using the on screen keyboard 4 Tap GSCN to set SSB location using the on screen keyboard Based on the GSCN input frequency the SSB frequency chang...

Page 242: ...d by upconversion Users do not always use the instrument based on RF frequency In this case you can set it to Manual or Off Auto Setting radio frequency to center frequency Manual Setting radio frequency as required Off Setting radio frequency to 0 12 Tap PDSCH Configuration or the Configuration icon on the screen to set PDSCH EVM in the PDSCH EVM Setting window appeared a Tap Data and select Data...

Page 243: ...en pos2 and pos3 to set the PDSCH DM RS position for mapping type A Select DM RS Additional Position to set the Position for additional DM RS in DL Select DM RS Duration between Single and Double Set Single when single symbol DM RS is used or Double when double two symbols are used Set Antenna Port to be used as reference for initial synchronization for DM RS Usable antenna port is determined by C...

Page 244: ...se it shows as in value Selected RB s EVM vs Subcarrier measurement with 5G NR NOTE You can move purple scroll bar right and left once tapped activated to set the specific RB number If you tap the Magnifier icon you can check the selected RB s EVM and subcarrier information and the mean for resource elements with assigned PDSCH in each RB 12 subcarriers x 14 symbols ...

Page 245: ...PBCH block since the synchronization signal and PBCH channel are packed as a single block that always moves together SSB should be detected first in 5G NR frame The following table shows the setting criteria based on the operating frequency Operating Frequency L Case SCS Slots in a burst period slot duration 3 GHz FR1 4 A 2 8 14 n 15 kHz 5 1 ms B 4 8 16 20 28 n 30 kHz 10 0 5 ms C 2 8 14 n 30 kHz 1...

Page 246: ...indow of SS transmission among 4 8 and 64 Refer to the selection criteria based on the table in Step 2 8 Tap SSB Periodicity and select the options from 5 ms 10 ms 20 ms 40 ms 80 ms 160 ms The SS burst period SSB periodicity is defined by each base station and network configurable 20 ms is the default for the initial cell selection 9 Tap to switch PCI Physical Cell ID to Manual or Auto 10 Tap PCI ...

Page 247: ...frequency domain is two consecutive REs Select DM RS Type A Position between pos2 and pos3 to set the PDSCH DM RS position for mapping type A Select DM RS Additional Position to set the Position for additional DM RS in DL Select DM RS Duration between Single and Double Set Single when single symbol DM RS is used or Double when double two symbols are used Set Antenna Port to be used as reference fo...

Page 248: ...Using 5G NR Signal Analyzer 236 Allocation Mapper measurement with 5G NR NOTE If you set PDSCH Analysis Area to On it shows a resource that is currently measuring PDSCH EVM ...

Page 249: ...P Primary Synchronization Signal Reference Signal Received Power average power measurement through all the primary sync signals S SS SINR Secondary Synchronization Signal Signal to Interference Plus Noise Ratio linear average over the power contribution in Watts of the resource elements carrying secondary synchronization signals divided by the linear average of the noise and interference power con...

Page 250: ... for one signal with the strongest RSRP for LTE carrier measuring PCI SSB Index S SS RSRP P SS RSRP P SS SNR S SS SINR S SS RSRQ for one signal with the strongest S SS RSRP for NR carrier b Normal measuring PCI RSRP RSRQ P SS SNR S SS SINR S SS RSSI P SS Power S SS Power for six signals with top down order based on the strongest RSRP signal for LTE carrier measuring PCI SSB Index S SS RSRP P SS RS...

Page 251: ...0 ms 40 ms 80 ms or 160 ms The SS burst period SSB periodicity is defined by each base station and network configurable 20 ms is the default for the initial cell selection k Tap the Auto Search box and select the options from Auto Preamp Atten or Manual Auto Preamp Atten to set preamp and attenuation automatically or Manual for user defined settings l Tap the Start button in Auto Search box to sea...

Page 252: ... information without changing the measurement mode to Beam Analyzer The beam information pops up for the selected carrier Select the AutoScale icon to automatically set the reference and attenuation level Each time you tap this both Y axis scale and input attenuation level change to be optimized with some margin Select the Quick Save icon to capture the current screen Select the Close icon to clos...

Page 253: ...r provides combined functions which are available in Carrier Scanner in 5G NR mode and Channel Scanner in LTE mode NSA Analyzer provides Channel Scanner function that is a radio receiver that can automatically tune or scan two or more discrete frequencies and multi channels indicating when it finds a signal on one of them and then continuing scanning when that frequency goes silent ...

Page 254: ...ing PCI SSB Index S SS RSRP P SS RSRP P SS SNR S SS SINR S SS RSRQ for eight signals with top down order based on the strongest S SS RSRP signal for NR carrier 5 Tap Trigger to set Internal External or GPS as required a Internal when starting a signal processing using the internal reference clock and creating a trigger b External when starting a signal processing based on the external input trigge...

Page 255: ...ch SCS type and the number of SSB automatically or the Stop button to set the SSB period based on the base station Once the Start button is tapped the progress bar appears m Tap the SSB Frequency button and input the required value using the on screen keyboard n Tap the GSCN box and input the required value using the on screen keyboard Based on the GSCN input frequency the SSB Frequency Sync Raste...

Page 256: ...eyboard j Tap to switch the Cyclic Prefix box to Extended or Normal 4 Once the carrier setup is done the carrier setup information appears on the top left screen NSA scanner measurement with LTE and NR carrier when taped LTE carrier NOTE If you want to see the constellation information tap and select the carrier number that you want to check If tapped the carrier information will be highlighted in...

Page 257: ...QP menu in JDMapCreator For more information on how to use the JDMapCreator see the JDMapCreator 2 0 User Guide 1 Plug in your USB flash drive that has a map file in mcf file type created in JDMapCreator 2 Tap the Load icon on the side bar 3 Navigate the map file you want to open The File Information pane displays the file properties including its name size type and date modified 4 Tap the Load bu...

Page 258: ...SRP for NR carrier b Normal measuring PCI RSRP RSRQ P SS SNR S SS SINR S SS RSSI P SS Power S SS Power for six signals with top down order based on the strongest RSRP signal for LTE carrier measuring PCI SSB Index S SS RSRP P SS RSRP P SS SNR S SS SINR S SS RSRQ for eight signals with top down order based on the strongest S SS RSRP signal for NR carrier 4 Tap Trigger to set Internal External or GP...

Page 259: ...0 ms 40 ms 80 ms or 160 ms The SS burst period SSB periodicity is defined by each base station and network configurable 20 ms is the default for the initial cell selection k Tap the Auto Search box and select the options from Auto Preamp Atten or Manual Auto Preamp Atten to set preamp and attenuation automatically or Manual for user defined settings l Tap the Start button in Auto Search box to sea...

Page 260: ...g the Load icon on the side bar Make sure the file extension is gomv 2 If Power is selected you can view the selected carrier s s power related parameters based on the Plot Item parameter RSRP RSRQ SINR or SNR that you have selected 3 If the PCI is set to Auto the point on the map appears with a color representing the highest S SS RSRP value When you select a point on the map a marker appears and ...

Page 261: ... import the site DB by creating the 5G site information form 1 Create the 5G site information with an excel file as below 2 Input the two mandatory fields Lat DecDeg and Long DecDeg 3 Input the Azimuth filed if you want to check the direction of antenna 4 Make sure to save the file as Comma delimited csv 5 Copy the file to the USB memory stick and insert it to the USB A or USB B port of the instru...

Page 262: ...th site information screen NOTE The purple icon indicates the base station site location and the direction of antenna If the site is beyond the latitude and longitude of the map file it will not show Route map measurement screen with 5G NSA Signal Analyzer ...

Page 263: ...p measurement screen Plot Point to Time with 5G NSA Signal Analyzer NOTE When you setup Plot Point to Time and tap the start testing button you cannot touch the screen to active After the waiting indicator stops the active indicator shows up ...

Page 264: ......

Page 265: ...ologies based on user demand Spectrum Analysis Spectrum RF Analysis Channel Power Occupied Bandwidth Spectrum Emission Mask ACLR Multi ACLR Spurious Emissions Power vs Time Power vs Time Symbol Power vs Time Frame Modulation Analysis Constellation Channel Mapper Control Channel Subframe Frame Time Alignment Error Frequency Time Error Histogram OTA Analysis OTA Channel Scanner OTA ID Scanner OTA Mu...

Page 266: ...A Analysis OTA Channel Scanner OTA ID Scanner OTA Multipath Profile OTA Control Channel OTA Route Map or Freq Time Power Variation Conducting spectrum measurements Spectrum Setting measure setup After configuring spectrum measurement in Configuring Spectrum Measurements you can set the measure setup to continue your measurement The measurement settings can be saved and recalled as a file by select...

Page 267: ...up and load the file onto the instrument using the Save Load icons on the side bar 1 Tap the Setup icon on the side bar 2 Tap Bandwidth from the following choices 5 MHz 10 MHz 15 MHz or 20 MHz 3 Tap to switch Signal Tech Type to TDD or FDD 4 Tap Menu BW AVG Average to set the number of measurements to be averaged using the on screen keyboard The input value range is from 1 to 100 Setting limit 1 T...

Page 268: ...p to switch the Test Limits to On or Off to enable or disable Pass Fail indication The result table color for Pass is green and the result table color for Fail is red 3 Tap High Limit to set the upper threshold using the on screen keyboard 4 Optional Tap the Save icon on the side bar and select the save option form the choices available for your measurement mode Occupied bandwidth with DSS Analyze...

Page 269: ...ng Limit 1 Tap Menu Limit 2 Tap to switch the Test Limits to On or Off to enable or disable Pass Fail indication The result table color for Pass is green and the result table color for Fail is red 3 Optional Tap the Save icon on the side bar and select the save option form the choices available for your measurement mode Spectrum emission mask measurement with DSS Analyzer If Lower Peak or Upper Pe...

Page 270: ...5G DSS Analyzer Multi ACLR The Multi ACLR measurement is used to perform multi channel ACLR measurements with as many channels as possible It helps you to measure ACLR in multi channel transmitting Base Station environment Setting measure setup After configuring spectrum measurement in Configuring Spectrum Measurements you can set the measure setup to continue your measurement The measurement sett...

Page 271: ...cessary channel bandwidth and modulated signal The CellAdvisor 5G indicates either Pass or Fail based on the specified limit of the signal Setting measure setup After configuring spectrum measurement in Configuring Spectrum Measurements you can set the measure setup to continue your measurement The frequency setting is not used in the Spurious Emissions mode The measurement settings can be saved a...

Page 272: ...value using the on screen keyboard 5 Tap Menu BW AVG Average to set the number of measurements to be averaged using the on screen keyboard The input value range is from 1 to 100 Setting limit 1 Tap Menu Limit 2 Tap to switch the Test Limits to On or Off to enable or disable Pass Fail indication 3 Optional Tap the Save icon on the side bar and select the save option form the choices available for y...

Page 273: ...n screen keyboard The PCI switches to Manual 7 Select MIMO between 2x2 and 4x4 to set the number of antenna ports If the MIMO is set to 2x2 the antenna ports 2 and 3 are disabled 8 Select Cyclic Prefix between Normal and Extended Cyclic prefix works as a buffer region or guard interval to protect the OFDM signals from inter symbol interference Normal Intended to be sufficient for the majority of s...

Page 274: ... Save Load icons on the side bar 1 Tap the Setup icon on the side bar 2 Tap Bandwidth from the following choices 5 MHz 10 MHz 15 MHz or 20 MHz 3 Tap to switch Signal Tech Type to TDD or FDD 4 Tap Slot Number from 0 to 19 5 Tap to switch PCI Physical Cell ID to Manual or Auto Auto lets the instrument detect the Physical Cell ID for the DSS signal automatically Manual sets the specific Physical Cell...

Page 275: ...st limits On Off High Limit using the on screen keyboard Transition Period Test limits On Off High Limit using the on screen keyboard 3 Optional Tap the Save icon on the side bar and select the save option form the choices available for your measurement mode Power vs Time Slot measurement with DSS Analyzer NOTE You can set the number of slot from 0 to 19 by tapping the Slot No box using the on scr...

Page 276: ...tended and then to set the number of PHICH groups Ng 1 6 1 2 1 or 2 The PHICH group value Ng is decided based on the number of PHICH groups per subframe PHICH duration is a higher layer parameter configured either as Normal or Extended that says the demodulator how many symbols per subframe are used by PHICH Normal There are 8 PHICH sequences in one PHICH group 4 symbols Extended There are 4 PHICH...

Page 277: ... a subframe select a specific modulation type to get more accurate EVM 12 Tap PDSCH Threshold to set the threshold for PDSCH and enter a value by using the on screen keyboard 13 Tap PDSCH Precoding to set On or Off to enable or disable the PDSCH precoding 14 Tap Menu Display and select Reset to refresh your measurement screen Setting limit 1 Tap Menu Limit 2 Tap NR Limit and set the limits dependi...

Page 278: ... on the side bar and select the save option form the choices available for your measurement mode Constellation measurement with DSS Analyzer Channel mapper CellAdvisor 5G DSS Channel mapper displays NR and LTE signal location based on sub carrier and symbol spacing with different colors within the resource block Setting measure setup After configuring spectrum measurement in Configuring Spectrum M...

Page 279: ...nces in one PHICH group 4 symbols Extended There are 4 PHICH sequences in one PHICH group 2 symbols When NR is selected as Technology do the following steps a Select Bandwidth MHz from the following choices 20 15 10 or 5 b Select Sub Carrier Spacing as 15 kHz Case A The standard for NR SCS is 15 kHz and CellAdvisor 5G supports 15 kHz of sub carrier spacing 4 Tap Antenna Port to assign an antenna p...

Page 280: ...es the constellation for the specified control channel as well as modulation accuracy of the control channel at the specified subframe Setting measure setup After configuring spectrum measurement in Configuring Spectrum Measurements you can set the measure setup to continue your measurement The measurement settings can be saved and recalled as a file by selecting File Type as Setup and load the fi...

Page 281: ...set the number of OFDM symbols used for transmitting PDCCHs in a subframe Manual sets the number of OFDM symbols manually The set of OFDM symbols that can be used for PDCCH in a subframe is given by 0 2 3 or 4 in 1 4 MHz bandwidth and 1 2 or 3 in other bandwidths 7 Tap CFI and input a value from 1 to 3 as desired using the on screen keyboard 8 Tap SSB frequency and input the value using the on scr...

Page 282: ...gnal for power Power PSS Test limits On Off High Limit Low Limit Note that based on the Reference Mode you have chosen from Menu Reference Mode between Absolute and Relative you can set the first high low limit when you chose absolute and second high low limit when you chose relative Secondary Synchronization Signal for power Power SSS Test limits On Off High Limit Low Limit Note that based on the...

Page 283: ...on Signal power S SS Power Test limits On Off High Limit Low Limit Note that based on the Reference Mode you have chosen from Menu Reference Mode between Absolute and Relative you can set the first high low limit when you chose absolute and second high low limit when you chose relative Physical Broadcast Channel Power PBCH Power Test limits On Off High Limit Low Limit Note that based on the Refere...

Page 284: ...n Normal and Extended Cyclic prefix works as a buffer region or guard interval to protect the OFDM signals from inter symbol interference Normal Intended to be sufficient for the majority of scenarios Extended Intended for scenarios with particularly high delay spread d Select PHICH Ng between Normal and Extended and then to set the number of PHICH groups Ng 1 6 1 2 1 or 2 The PHICH group value Ng...

Page 285: ...If two or more modulation types are used in a frame select Auto If the PDSCH uses the same modulation type in a frame or in a subframe select a specific modulation type to get more accurate EVM 12 Tap PDSCH Threshold to set the threshold for PDSCH and enter a value by using the on screen keyboard 13 Tap PDSCH Precoding to set On or Off to enable or disable the PDSCH precoding 14 Tap EVM Detection ...

Page 286: ...hysical Broadcast Channel for power PBCH Power Test limits On Off High Limit Low Limit Note that based on the Reference Mode you have chosen from Menu Reference Mode between Absolute and Relative you can set the first high low limit when you chose absolute and second high low limit when you chose relative Time error Time Error Test limits On Off High Limit Low Limit 3 Tap LTE Limit and set the lim...

Page 287: ...ou chose relative Physical Broadcast Channel Power PBCH Power Test limits On Off High Limit Low Limit Note that based on the Reference Mode you have chosen from Menu Reference Mode between Absolute and Relative you can set the first high low limit when you chose absolute and second high low limit when you chose relative Subframe Power Subframe Power Test limits On Off High Limit Low Limit OFDM Sym...

Page 288: ...x next to Sumbframe No If you enter subframe number 1 you will see NR data Right before the Channel Summary you can tap the Chart icon to see the result in a chart view Subframe measurement with DSS Analyzer bar chart NOTE You can tap the Reset button next to Subframe Summary on the right side of the screen to refresh the measurement result screen ...

Page 289: ...ix between Normal and Extended Cyclic prefix works as a buffer region or guard interval to protect the OFDM signals from inter symbol interference Normal Intended to be sufficient for the majority of scenarios Extended Intended for scenarios with particularly high delay spread d Select PHICH Ng between Normal and Extended and then to set the number of PHICH groups Ng 1 6 1 2 1 or 2 The PHICH group...

Page 290: ...ulation types are used in a frame select Auto If the PDSCH uses the same modulation type in a frame or in a subframe select a specific modulation type to get more accurate EVM 11 Tap PDSCH Threshold to set the threshold for PDSCH and enter a value by using the on screen keyboard 12 Tap PDSCH Precoding to set On or Off to enable or disable the PDSCH precoding 13 Tap EVM Detection Mode to set Combin...

Page 291: ...s On Off High Limit Low Limit Note that based on the Reference Mode you have chosen from Menu Reference Mode between Absolute and Relative you can set the first high low limit when you chose absolute and second high low limit when you chose relative 3 Tap LTE Limit and set the limits depending on your selected measurement mode To set the limit for Select Set Frequency error Frequency error Test li...

Page 292: ...ff High Limit Low Limit Note that based on the Reference Mode you have chosen from Menu Reference Mode between Absolute and Relative you can set the first high low limit when you chose absolute and second high low limit when you chose relative Frame Average Power Frame Avg Power Test limits On Off High Limit Low Limit OFDM Symbol Power OFDM Symbol Power Test limits On Off High Limit Low Limit Magn...

Page 293: ...ween Normal and Extended and then to set the number of PHICH groups Ng 1 6 1 2 1 or 2 The PHICH group value Ng is decided based on the number of PHICH groups per subframe PHICH duration is a higher layer parameter configured either as Normal or Extended that says the demodulator how many symbols per subframe are used by PHICH Normal There are 8 PHICH sequences in one PHICH group 4 symbols Extended...

Page 294: ...e instrument using the Save Load icons on the side bar 1 Tap the Setup icon on the side bar 2 Tap to switch Radio Config and set Duplex Type FDD TDD DSS Type Co channel Adjacent channel and Technology LTE NR and other related parameters as below You can select Co channel to find NR frequency based on the LTE operating frequency in co channel and select Adjacent channel to search both LTE and NR fr...

Page 295: ...ate EVM 6 Tap PDSCH Threshold to set the threshold for PDSCH and enter a value by using the on screen keyboard 7 Tap PDSCH Precoding to set On or Off to enable or disable the PDSCH precoding General setting You can configure trigger setting in the general setting section 1 Tap the Configuration icon in the detected list table or Setup Configuration 2 Tap Trigger to set Internal External or GPS as ...

Page 296: ...ed on the GSCN input frequency the SSB Frequency is automatically changed l Tap to switch LTE PCI Mode to Manual or Auto and input a value from 0 to 503 The PCI switches to Manual m Tap NR PCI Mode to Manual or Auto and input a value from 0 to 1007 The PCI switches to Manual NOTE You can set Auto to let the instrument detect the Physical Cell ID for the LTE NR signal automatically and Manual to se...

Page 297: ...nel to find NR frequency based on the LTE operating frequency in co channel and select Adjacent channel to search both LTE and NR frequency Note that Adjacent channel will be available in the next release When LTE is selected as Technology do the following steps a Select Bandwidth MHz from the following choices 20 15 10 or 5 b Select MIMO between 2x2 and 4x4 c Select Cyclic Prefix between Normal a...

Page 298: ...et Auto to let the instrument detect the Physical Cell ID for the LTE NR signal automatically and Manual to set the specific Physical Cell ID for the LTE NR signal manually in order to speed up the synchronization with a BTS 9 Tap PDSCH and then select the PDSCH modulation type option Auto QPSK 16 QAM 64 QAM 256 QAM LTE E TM3 3 LTE E TM3 2 LTE E TM3 1a LTE E TM3 1 LTE E TM2a LTE E TM2 LTE E TM1 2 ...

Page 299: ...nel will be available in the next release When LTE is selected as Technology do the following steps a Select Bandwidth MHz from the following choices 20 15 10 or 5 b Select MIMO between 2x2 and 4x4 to set the number of antenna ports If the MIMO is set to 2x2 the antenna ports 2 and 3 are disabled c Select Cyclic Prefix between Normal and Extended Cyclic prefix works as a buffer region or guard int...

Page 300: ... NOTE You can set Auto to let the instrument detect the Physical Cell ID for the LTE NR signal automatically and Manual to set the specific Physical Cell ID for the LTE NR signal manually in order to speed up the synchronization with a BTS 10 Tap PDSCH and then select the PDSCH modulation type option Auto QPSK 16 QAM 64 QAM 256 QAM LTE E TM3 3 LTE E TM3 2 LTE E TM3 1a LTE E TM3 1 LTE E TM2a LTE E ...

Page 301: ...mal Intended to be sufficient for the majority of scenarios Extended Intended for scenarios with particularly high delay spread d Select PHICH Ng between Normal and Extended and then to set the number of PHICH groups Ng 1 6 1 2 1 or 2 The PHICH group value Ng is decided based on the number of PHICH groups per subframe PHICH duration is a higher layer parameter configured either as Normal or Extend...

Page 302: ... modulation type to get more accurate EVM 11 Tap PDSCH Threshold to set the threshold for PDSCH and enter a value by using the on screen keyboard 12 Tap PDSCH Precoding to set On or Off to enable or disable the PDSCH precoding 13 Tap Menu Display and select EVM or Power The screen changes according to the selected options 14 Tap Menu Display and select Reset to refresh your measurement screen You ...

Page 303: ... time and geographical position and presents it in a geographical map as a measurement point All the collected measurements can be exported for post processing purposes including data of the eight strongest beams for each measurement point including its measurement time and geographical location Loading a map To use any features related to maps you need to download and install the maps on the Cell...

Page 304: ...o GPS or Position or Time a To collect data plot points automatically as you move around in a vehicle or outside outdoor select GPS and then tap to switch to the Screen Mode between Map and Full With the Map setting you can view only the collected points that can be seen within the boundary of the loaded map With the Full setting you can view all the collected points of the route without the loade...

Page 305: ...H in a subframe is given by 0 2 3 or 4 in 1 4 MHz bandwidth and 1 2 or 3 in other bandwidths 9 Tap CFI and input a value from 1 to 3 as desired using the on screen keyboard 10 Tap SSB frequency and input the value using the on screen keyboard 11 Tap GSCN and input the value from 2 to 26639 using the on screen keyboard If you need to search SSB based on ARFCN raster it would take too long time sinc...

Page 306: ...ng the Load icon on the side bar Make sure the file extension is gomv 2 If the PCI is set to Auto the point on the map appears with a color representing the largest S SS RSRP value When you select a point on the map a marker appears and the Information window appears on the right panel 3 Set the PCI to Manual and tap the Select button The Select PCI window appears 4 Select PCI on the left and then...

Page 307: ...5G site information with an excel file as below 2 Input the two mandatory fields Lat DecDeg and Long DecDeg 3 Input the Azimuth filed if you want to check the direction of antenna 4 Make sure to save the file as Comma delimited csv 5 Copy the file to the USB memory stick and insert it to the USB A or USB B port of the instrument 6 Tap the Load icon on the side bar 7 Import the saved file Once the ...

Page 308: ...rection of antenna If the site is beyond the latitude and longitude of the map file it will not show Route map measurement screen with DSS Signal Analyzer NOTE If the Plot Point is set to Position you can tap the estimated area by point If you tap incorrectly you can tap Undo icon on the map and then it will delete the point you have tapped incorrectly ...

Page 309: ...Cyclic Prefix between Normal and Extended Cyclic prefix works as a buffer region or guard interval to protect the OFDM signals from inter symbol interference Normal Intended to be sufficient for the majority of scenarios Extended Intended for scenarios with particularly high delay spread d Select PHICH Ng between Normal and Extended and then to set the number of PHICH groups Ng 1 6 1 2 1 or 2 The ...

Page 310: ...ecific Physical Cell ID for the LTE NR signal manually in order to speed up the synchronization with a BTS 10 Tap PDSCH and then select the PDSCH modulation type option Auto QPSK 16 QAM 64 QAM 256 QAM LTE E TM3 3 LTE E TM3 2 LTE E TM3 1a LTE E TM3 1 LTE E TM2a LTE E TM2 LTE E TM1 2 or LTE E TM1 1 If two or more modulation types are used in a frame select Auto If the PDSCH uses the same modulation ...

Page 311: ...istance box and input the value that you want to compensate for distance When distance is entered the time will show the value with distance correction Make sure the default value for Distance is 0 Frequency Time Power variation by power with DSS Analyzer ...

Page 312: ......

Page 313: ...ignal Quality Modulation Quality MIMO Time Alignment Error CA Time Alignment Error Selecting mode and measure To start measurement do the following steps 1 Tap 5G TM Signal Analyzer on the MODE panel 2 Tap any measurement mode from the following choices Spectrum Analysis BS Output Power Unwanted Emissions Occupied Bandwidth ACLR Multi ACLR Operating Band Unwanted Emissions or Transmitter Spurious ...

Page 314: ...1a FR1 TM3 2 FR1 TM3 5 Based on the above setting tap Test Model FR2 and select the options from the following choices FR2 TM1 1 FR2 TM2 FR2 TM3 1 6 Tap EIRP Settings and do the following a Select Set Max to EIRP1 to save the currently measured maximum value to EIRP1 b Select Set Max to EIRP2 to save the currently measured maximum value to EIRP2 c Select Clear Max to clear the currently measured m...

Page 315: ...lable for your measurement mode BS output power measurement with 5G TM Conducting unwanted emissions Occupied bandwidth The Occupied Bandwidth measures the percentage of the transmitted power within a specified bandwidth The percentage is typically 99 Setting measure setup Before starting the measurement you need to set Spectrum measurements displayed on the quick access and display tab See Config...

Page 316: ...itch the Test Limits to On or Off to enable or disable Pass Fail indication The result table color for Pass is green and the result table color for Fail is red 3 Tap High Limit to set the upper threshold using the on screen keyboard 4 Optional Tap the Save icon on the side bar and select the save option form the choices available for your measurement mode Occupied bandwidth measurement with 5G TM ...

Page 317: ...Hz You can only select the Duplex Type as TDD 3 Based on the above setting tap Test Model FR1 and select the options from the following choices FR1 TM1 1 FR1 TM1 2 FR1 TM3 1 FR1 TM3 1a FR1 TM3 2 FR1 TM3 4 Based on the above setting tap Test Model FR2 and select the options from the following choices FR2 TM1 1 FR2 TM2 FR2 TM3 1 5 Tap BS Type and select the option from 1 C 1 H 1 O or 2 O Set 1 C Con...

Page 318: ...io Setup pop up window appears If you select the operating frequency as FR1 select from the following SCS 15 kHz 5 10 15 20 25 30 40 50 MHz SCS 30 kHz 5 10 15 20 25 30 40 50 60 70 80 90 100 MHz SCS 60 kHz 10 15 20 25 30 40 50 60 70 80 90 100 MHz Tap Duplex Type between FDD and TDD as required FDD both uplink and downlink can transmit at the same time at different spectrum frequencies TDD both upli...

Page 319: ...he rectangle with value using the on screen keyboard Operating band unwanted emission The operating band unwanted emissions define all unwanted emissions in the downlink operating band plus the frequency ranges 10 MHz above and 10 MHz below the band Unwanted emissions outside of this frequency range are limited by a spurious emissions requirement For a BS supporting multi carrier or intra band con...

Page 320: ... 1 O or 2 O Set 1 C Conducted 1 H Hybrid for multi band operation with mapping of transceivers to one or more antenna connectors 1 C or TAB transceiver array boundary connectors for 1 H Set 1 O when BS operates at FR1 and 2 0 when BS operates at FR2 b Tap Category and select the option from Wide Area BS A Wide Area BS B Medium Range BS or Local Area BS The category is defined with base station typ...

Page 321: ...by selecting File Type as Setup and load the file onto the instrument using the Save Load icons on the side bar 1 Tap the Setup icon on the side bar 2 Tap to switch Setting to User if you want user defined setting and do the following steps a Tap Radio Setup then the Radio Setup pop up window appears if you choose FR1 select from the following SCS 15 kHz 5 10 15 20 25 30 40 50 MHz SCS 30 kHz 5 10 ...

Page 322: ...lex Type as TDD 6 Tap BS Type and select the option from 1 C 1 H 1 O or 2 O Set 1 C Conducted 1 H Hybrid for multi band operation with mapping of transceivers to one or more antenna connectors 1 C or TAB transceiver array boundary connectors for 1 H Set 1 O when BS operates at FR1 and 2 0 when BS operates at FR2 7 Tap Measure Type and select the option from Transmitted or Receiver Based on the mea...

Page 323: ...ents apply only to TDD operation of the BS Setting measure setup Before starting the measurement you need to set Spectrum measurements displayed on the quick access and display tab See Configuring Spectrum Measurements for more details The measurement settings can be saved and recalled as a file by selecting File Type as Setup and load the file onto the instrument using the Save Load icons on the ...

Page 324: ...ed to compensate for phase differences between symbols caused by upconversion Users do not always use the instrument based on RF frequency In this case you can set it to Manual or Off Auto Setting radio frequency to center frequency Manual Setting radio frequency as required Off Setting radio frequency to 0 NOTE When calculating Symbol Phase Compensation you can use the following formula It is a f...

Page 325: ...he ideal symbols and the measured symbols after the equalization This difference is called the error vector OTA modulation quality is defined by the difference between the measured carrier signal and an ideal signal Modulation quality can e g be expressed as Error Vector Magnitude EVM The Error Vector Magnitude is a measure of the difference between the ideal symbols and the measured symbols after...

Page 326: ...R1 TM3 1a FR1 TM3 2 FR1 TM3 5 Based on the above setting tap Test Model FR2 and select the options from the following choices FR2 TM1 1 FR2 TM2 FR2 TM3 1 6 Tap to switch Phase Correction to On or Off Phase Correction is a way of optimizing EVM performance When you switch it On it will decrease inter symbol interference and compensate distortion caused by a filter applying to each OFDM symbol 7 Tap...

Page 327: ...ent error in Tx diversity is specified as the delay between the signals from two antennas at the antenna ports Setting measure setup Before starting the measurement you need to set Spectrum measurements displayed on the quick access and display tab See Configuring Spectrum Measurements for more details The measurement settings can be saved and recalled as a file by selecting File Type as Setup and...

Page 328: ...elect from the following choices Auto Manual or Off Symbol Phase Compensation is used to compensate for phase differences between symbols caused by upconversion Users do not always use the instrument based on RF frequency In this case you can set it to Manual or Off Auto Setting radio frequency to center frequency Manual Setting radio frequency as required Off Setting radio frequency to 0 NOTE Whe...

Page 329: ... antenna port To see it with chart view tap Time Offset button at the right bottom of the screen MIMO time alignment error with time offset chart with 5G TM CA time alignment error CellAdvisor 5G Carrier Aggregation time alignment error measures time error of each signal that has different carrier frequency and show difference between measured time errors ...

Page 330: ...ions from the following choices FR1 TM1 1 FR1 TM1 2 FR1 TM3 1 FR1 TM3 1a FR1 TM3 2 FR1 TM3 6 Based on the above setting tap Test Model FR2 and select the options from the following choices FR2 TM1 1 FR2 TM2 FR2 TM3 1 7 Tap to switch Phase Correction to On or Off Phase Correction is a way of optimizing EVM performance When you switch it On it will decrease inter symbol interference and compensate d...

Page 331: ...CellAdvisor 5G User s Guide 319 CA time alignment error with 5G TM NOTE You can tap Configuration icon on the table and set the carrier number from 1 to 8 and center frequency for each carrier ...

Page 332: ......

Page 333: ...ndent of the span setting The frequency is extended up to 18 5 GHz in addition to existing 24 GHz to 40 GHz Before starting the Internal RF Power Meter you need to set Spectrum measurements displayed on the quick access and display tab See Configuring Spectrum Measurements for more details Setting measure setup 1 Tap the Setup icon on the side bar 2 Tap Resolution and select the resolution option ...

Page 334: ...cess and display tab See Configuring Spectrum Measurements for more details Connecting a cable There are two types of power sensors Directional power sensors are used in in service power measurement Terminating power sensors are used in out of service power measurement See below to check the external power sensor type Part Number Description Frequency Range Power Range JD731B Directional Power Sen...

Page 335: ... sensor connected to the instrument Connecting an external power sensor is mandatory Terminating power sensor connection Directional power sensor connection 1 Connect an external power sensor to the USB Host port of the CellAdvisor 5G and to the RF output port of BTS as shown in the below figure The CellAdvisor 5G automatically detects and initializes the power sensor connected to the instrument C...

Page 336: ... Forward Peak Power Pulse Power or VSWR For JD733A select the power range option Forward Avg Power Reverse Avg Power Forward Peak Power or VSWR 2 Tap the Setup icon on the side bar 3 Tap Resolution and select the resolution option from the following choices 0 Displays the reading with no decimal place 1 Displays the reading with one decimal place 2 Displays the reading with no decimal place 4 Tap ...

Page 337: ...surement You can measure and understand a trend of a system output in operation where output power constantly varies depending on the amount of calls being processed by the BTS or Repeater In addition the Log graph benefits you to easily examine the discontinuance of output power caused by the transmission problems or defective connection ...

Page 338: ......

Page 339: ...he CPRI control signals and extracts the IQ data transmitted between the BBU and RRH to monitor and analyze the uplink interferences and the downlink signals You can also monitor current and history CPRI alarm status for LOS and LOF displayed on the interference measurement screen The RFoCPRI testing provides following measurements Spectrum Analysis Spectrum Spectrogram Spectrum Replayer Selecting...

Page 340: ...ion is used in the RFoCPRI mode including spectrum spectrogram and spectrum replayer measurements Setting frequency You can set the frequency with either frequency or channel number If a frequency to be set matches to the frequency corresponding to the selected channel standard the instrument calculates its channel number and updates the screen with it automatically To set the frequency with cente...

Page 341: ... one division on the horizontal scale The default setting is 10 dB per division and the maximum value can be set up to 20 dB 1 Tap Scale Division under Amp Scale 2 Enter a value between 1 and 20 by using the on screen keyboard and tap Apply Setting external offset You can turn the External Offset on and manually set the external offset value An offset consists of a cable loss and a user offset and...

Page 342: ...al bandwidths 1 4 MHz and 3 MHz RBW from 1 kHz to 30 kHz For signal bandwidths 5 MHz 10 MHz 15 MHz and 20 MHz RBW from 1 kHz to 100 kHz 4 Tap VBW to set the video bandwidth and choose one of the following options 100 kHz 30 kHz 10 kHz or 7 5 kHz Setting average You can set the number of measurements to be averaged for the trace presentation in the Spectrum Spectrogram modes A maximum of 100 times ...

Page 343: ...d displays larger maximum values or smaller minimum values on the screen 5 To select the detection option tap Detectors and then complete one of the followings Select Normal to display Random noise better than the peak without missing signals Select Peak to display The highest value in each data point Select RMS to display The root mean squared average power across the spectrum Select Negative Pea...

Page 344: ...e interference analysis you need to choose a network technology to analyze 1 Tap the Setup icon on the side bar of each measurement mode 2 Tap Rx Settings Technology and select a desired network technology form the menu bar LTE default WCDMA Depending on the network technology you selected the settings on the Rx Parameter menu change accordingly ...

Page 345: ...AxC 6 or AxC 7 Not all of these are activated depending on the bandwidth setting of the network technology you selected c Enter a value by using the on screen keyboard NOTE The Antenna Carrier AxC is the amount of digital baseband IQ U plane data necessary for either reception or transmission of one carrier at one independent antenna element The number of required AxC Container for a basic frame a...

Page 346: ...Using RFoCPRI Analyzer 334 Rx Settings with RFoCPRI Analyzer ...

Page 347: ... and select the CPRI link rate option from 614 4 Mbps 1228 8 Mbps 2457 6 Mbps 3072 0 Mbps 4915 2 Mbps 6144 0 Mbps 9830 4 Mbps or 10137 6 Mbps NOTE It is important that you set the link rate correctly to avoid any misleading LOS and LOF alarms displayed on the screen 3 To turn on or off the through mode tap On or Off in Thru line 4 To set the Tx Clock tap Recovered default in Clock box ...

Page 348: ... active marker position as the alarm reference if you have enabled a marker on the spectrum Line Makes the reference line as the alarm reference b If you have set the alarm reference to Line tap the Reference Line to set a threshold for an alarm c Enter a value by tapping or and tap Apply d Tap Sound either On or Off to turn on off the alarm sound e Optional To adjust the volume for alarm sound ta...

Page 349: ...FoCPRI spectrum measurement Conducting spectrogram The Spectrogram is particularly useful when attempting to identify periodic or intermittent signals as it captures spectrum activity over time and uses various colors to differentiate spectrum power levels When the directional antenna is used to receive the signal you will see a change in the amplitude of the tracked signal as you change the direc...

Page 350: ...nd then select a desired save option for your measurement mode NOTE You can use the Limit menu to analyze your measurements with the display line RFoCPRI interference measurement in spectrogram Performing spectrum replayer The Spectrum Replayer lets you retrieve and replay recorded spectrum analyzer traces in interference analysis mode These traces can be played back in the spectrogram or RSSI You...

Page 351: ... This key becomes activated when you play logged data in the Spectrogram mode NOTE If you connect a USB drive do not remove it while playing to prevent freezing the USB port which will require you to restart the instrument to get a USB drive recognized again Setting Display You can select the display option to view data in a different mode 1 Select the display option from Spectrum or Spectrogram i...

Page 352: ......

Page 353: ...z and FR2 up to 40 GHz CA5000 F001 O Frequency for 5G NR FR1 up to 6 GHz with optic HW CA5000 F002 O Frequency for 5G NR FR1 up to 6 GHz and FR2 up to 40 GHz with optic HW CA5000F002N Frequency for 5G NR FR1 6 GHz and FR2 40 GHz with two RF ports CA5000F002N O Frequency for 5G NR FR1 6 GHz and FR2 40 GHz with optic HW and two RF ports Hardware Upgrade Options Catalog Number Description CA5000 FU02...

Page 354: ...0 S011 100 MHz bandwidth real time spectrum analyzer Requires B100 CA5000 S012 Upgrade RtSA BW from 50 MHz to 100 MHz Requires B100 and S010 CA5000 S013 Interference analyzer CA5000 S014 Route map CA5000 S015 Gate sweep CA5000 S016 Channel scanner CA5000S032 LTE LTE A FDD signal analyzer CA5000S033 LTE LTE A TDD signal analyzer CA5000S032 LTE LTE A FDD signal analyzer CA5000 S040 5G TF signal anal...

Page 355: ...MA mount antenna G700050431 CA5G soft carrying case G700050551 RF cable DC to 40 GHz K m to K f 0 8 m B RoHS information This appendix describes the RoHS Restriction of Hazardous Substances information which is a mandatory requirement from China The RoHS directive consists in the restriction on the use of certain hazardous substances in electrical or electronic equipment sold or used in the Europe...

Page 356: ...Appendix 344 ...

Page 357: ...345 ...

Page 358: ......

Page 359: ...ica Toll Free 1 844 GO VIAVI 1 844 468 4284 Latin America 52 55 5543 6644 EMEA 49 7121 862273 APAC 1 512 201 6534 All other regions www viavisolutions contacts Email TAC viavisolutions com Doc No 22128646 Rev 15 March 2021 English ...

Reviews: