297
Freq/Time/Power variation
Frequency, time, and power error variation shows the frequency, time, and power error trend based on the time elapsed.
Setting measure setup
After configuring spectrum measurement in "
Configuring Spectrum Measurements
", you can set the measure setup to continue your
measurement. The measurement settings can be saved and recalled as a file by selecting File Type as Setup and load the file onto
the instrument using the
Save/Load
icons on the side bar.
1
Tap the
Setup
(
)icon on the side bar.
2
Tap to switch
Carrier Auto Search
to
Start
to start searching the SSB frequency and apply it or to
Stop
to stop searching.
NOTE
If searching is unavailable, the instrument displays a pop-up message saying that it fails to detect NR (SSB)
frequency.
3
Tap to switch
Radio Config
and set
Duplex Type
(FDD/TDD),
DSS Type
(Co-channel/
Adjacent channel
), and
Technology
(LTE/NR) and other related parameters as below:
You can select Co-channel to find NR frequency based on the LTE operating frequency in co-channel and select Adjacent
channel to search both LTE and NR frequency. Note that Adjacent channel will be available in the next release.
When
LTE
is selected as
Technology
, do the following steps:
a
Select
Bandwidth
(MHz) from the following choices:
20
,
15
,
10
, or
5
.
b
Select
MIMO
between
2x2
to set the number of antenna ports.
If the MIMO is set to 2x2, the antenna ports 2 and 3 are disabled.
c
Select
Cyclic Prefix
between
Normal
and
Extended
.
Cyclic prefix works as a buffer region or guard interval to protect the OFDM signals from inter symbol interference.
▪
Normal
: Intended to be sufficient for the majority of scenarios
▪
Extended
: Intended for scenarios with particularly high delay spread.
d
Select
PHICH Ng
between
Normal
and
Extended
and then to set the number of PHICH groups (Ng) :
1/6
,
1/2
,
1
, or
2
.
The PHICH group value/Ng is decided based on the number of PHICH groups per subframe. PHICH duration is a higher
layer parameter configured either as Normal or Extended that says the demodulator how many symbols per subframe are
used by PHICH
.
▪
Normal
: There are 8 PHICH sequences in one PHICH group (4 symbols).
▪
Extended
: There are 4 PHICH sequences in one PHICH group (2 symbols).
When
NR
is selected as
Technology
, do the following steps:
a
Select
Sub-Carrier Spacing
as
15 kHz (Case A)
.
The standard for NR SCS is 15 kHz and CellAdvisor 5G supports 15 kHz of sub-carrier spacing.
4
Tap
Antenna Port
to assign an antenna port number automatically or manually, and select from
Auto
,
Antenna 0
, or
Antenna
1
.
If the MIMO is set to 2x2, the antenna ports 2 and 3 are disabled.
5
Tap to switch
CFI
to
Manual or Auto
.
▪
Auto
lets the instrument set the number of OFDM symbols used for transmitting PDCCHs in a subframe.
▪
Manual
sets the number of OFDM symbols manually. The set of OFDM symbols that can be used for PDCCH in a
subframe is given by 0, 2, 3 or 4 in 1.4 MHz bandwidth and 1, 2 or 3 in other bandwidths.
6
Tap
CFI
and input a value from 1 to 3 as desired using the on-screen keyboard.
7
Tap
SSB frequency
and input the value using the on-screen keyboard.
Summary of Contents for CellAdvisor 5G
Page 1: ...1 CellAdvisorTM 5G User s Guide ...
Page 2: ......
Page 18: ......
Page 22: ......
Page 110: ......
Page 146: ......
Page 182: ...Using LTE LTE A TDD Analyzer 170 CCDF measurement with LTE LTE A TDD Analyzer ...
Page 264: ......
Page 312: ......
Page 332: ......
Page 338: ......
Page 346: ...Using RFoCPRI Analyzer 334 Rx Settings with RFoCPRI Analyzer ...
Page 352: ......
Page 356: ...Appendix 344 ...
Page 357: ...345 ...
Page 358: ......