Using 5G NR Signal Analyzer
192
10
Tap
PCI
and input a value from 0 to 1007 using the on-screen keyboard.
The
PCI
switches to
Manual
.
11
Tap
SEM Config
to configure the following items:
a
Tap
BS Type
and select the option from
1-C/1-H
,
1-O
, or
2-O
.
Set 1-C (Conducted)/1-H (Hybrid) for multi-band operation with mapping of transceivers to one or more antenna
connectors (1-C) or TAB (transceiver array boundary) connectors for 1-H. Set 1-O when BS operates at FR1 and 2-0
when BS operates at FR2.
b
Tap
Category
and select the option from
Wide Area BS A
,
Wide Area BS B
,
Medium Range BS
, or
Local Area BS
.
The category is defined with base station type. Set Wide Area BS A/B for macro cell, Medium Range BS for micro cell,
and Local Area Base Station for pico cell.
c
Tap
Mask Type
and select the option from
KCA
or
3GPP
.
You can select the KCA to follow Korea Communications Agency standard (Korea-specific) or select 3GPP to follow
international standard.
12
Tap
Menu
>
BW/AVG
>
Average
to set the number of measurements to be averaged using the on-screen keyboard.
The input value range is from 1 to 100.
Setting limit
1
Tap
Menu
>
Limit
.
2
Tap to switch the
Test Limits
to
On
or
Off
to enable or disable Pass/Fail indication.
The result table color for Pass is green, and the result table color for Fail is red.
3
Optional.
Tap the
Save
hot key on the side bar and select the save option form the choices available for your measurement
mode.
Spectrum emission mask measurement with 5G NR
If Lower Peak
or Upper Peak indicate Fail, the mask line becomes red.
ACLR
The Adjacent Channel Power Ratio (ACPR) designated by the 3GPP WCDMA specifications as the Adjacent Channel Leakage
Power Ratio (ACLR), is the power contained in a specified frequency channel bandwidth relative to the total carrier power. It may
also be expressed as a ratio of power spectral densities between the carrier and the specified offset frequency band.
Setting measure setup
After configuring spectrum measurement in "
Configuring Spectrum Measurements
", you can set the measure setup to continue your
measurement. The measurement settings can be saved and recalled as a file by selecting File Type as Setup and load the file onto
the instrument using the
Save/Load
icons on the side bar.
1
Tap the
Setup
(
)icon on the side bar.
Summary of Contents for CellAdvisor 5G
Page 1: ...1 CellAdvisorTM 5G User s Guide ...
Page 2: ......
Page 18: ......
Page 22: ......
Page 110: ......
Page 146: ......
Page 182: ...Using LTE LTE A TDD Analyzer 170 CCDF measurement with LTE LTE A TDD Analyzer ...
Page 264: ......
Page 312: ......
Page 332: ......
Page 338: ......
Page 346: ...Using RFoCPRI Analyzer 334 Rx Settings with RFoCPRI Analyzer ...
Page 352: ......
Page 356: ...Appendix 344 ...
Page 357: ...345 ...
Page 358: ......