CellAdvisor 5G User's Guide
43
External Offset
Tap to manually set the external offset value from - 120 to 120 using the on- screen keyboard.
When you compensate for the external loss, input the negative values, and when you
compensate for the external gain, input the positive values.
Access
:
Menu
>
Amp/Scale
>
External Offset
Auto Scale
Tap to automatically set the reference and attenuation level. Each time you tap this, both Y-axis
scale and input attenuation level change to be optimized with some margin.
Access
:
Menu
>
Amp/Scale
>
Auto Scale
NOTE:
It is recommended that you set the
Attenuation
to
Auto
in most situations so that the level of the input attenuator
can be set automatically according to your input signal level.
Setting BW/AVG
You can manually set the Resolution Bandwidth (RBW), Video Bandwidth (VBW), and the proportional VBW based on the
designated RBW. Selecting
Auto
changes the value to correspond to your frequency span setting for RBW and to the current RBW
and VBW/RBW settings for VBW.
Access
:
on the Quick access and display tab or
Menu
>
BW/AVG
BW/AVG
The following is the definition of each key function:
Parameter
Definition
RBW
Tap
RBW
to set it manually. Tap a value between 1 Hz to 3 MHz. The RBW setting automatically changes to
Manual
.
Access
:
Menu
>
BW/AVG
>
RBW
RBW Mode
Manual/Auto
Toggle the
RBW Mode
to
Manual
or
Auto
. When you select Auto, it will be automatically set to an
approximate value for Span/100.
Access
:
Menu
>
BW/AVG
>
RBW
(Manual/Auto)
VBW
Tap
VBW
to set it manually. Tap a value between 1 Hz to 3 MHz. The VBW setting automatically changes to
Manual
.
Access
:
Menu
>
BW/AVG
>
VBW
VBW Mode
Manual/Auto
Toggle the
RBW Mode
to Manual or Auto.
Access
:
Menu
>
BW/AVG
>
VBW
(Manual/Auto)
VBW/RBW
Sets the proportional VBW based on the designated RBW. Select the ratio: 1, 0.3, 0.1, 0.03, 0.01, or 0.003.
Toggle the
VBW
and
RBW
to
Auto
.
Access
:
Menu
>
BW/AVG
>
VBW/RBW
Average
Sets the number of measurements to be averaged for the trace presentation. A maximum of 100 times of
averaging can be set.
Access
:
Menu
>
BW/AVG
>
Average
Summary of Contents for CellAdvisor 5G
Page 1: ...1 CellAdvisorTM 5G User s Guide ...
Page 2: ......
Page 18: ......
Page 22: ......
Page 110: ......
Page 146: ......
Page 182: ...Using LTE LTE A TDD Analyzer 170 CCDF measurement with LTE LTE A TDD Analyzer ...
Page 264: ......
Page 312: ......
Page 332: ......
Page 338: ......
Page 346: ...Using RFoCPRI Analyzer 334 Rx Settings with RFoCPRI Analyzer ...
Page 352: ......
Page 356: ...Appendix 344 ...
Page 357: ...345 ...
Page 358: ......