2
Tap to switch the
Test Limits
to
On
or
Off
to enable or disable Pass/Fail indication.
The result table color for Pass is green, and the result table color for Fail is red.
3
Optional.
Tap the
Save
icon on the side bar and select the save option form the choices available for your measurement mode.
Multi-ACLR measurement with DSS Analyzer
NOTE
You can set the Lowest Ref. Frequency and Highest Ref. Frequency by tapping the rectangle with value using the
on-screen keyboard.
Spurious emissions
The Spurious Emissions measurement is to identify or determine the power level of in-band or out-of-band spurious emissions
within the necessary channel bandwidth and modulated signal. The CellAdvisor 5G indicates either Pass or Fail based on the
specified limit of the signal.
Setting measure setup
After configuring spectrum measurement in "
Configuring Spectrum Measurements
", you can set the measure setup to continue your
measurement. The frequency setting is not used in the Spurious Emissions mode. The measurement settings can be saved and
recalled as a file by selecting File Type as Setup and load the file onto the instrument using the
Save/Load
icons on the side bar.
1
Tap the
Setup
(
)icon on the side bar.
2
Tap to switch
Signal Tech Type
to
TDD
or
FDD
.
3
Tap to switch
Measure Type
to
Full
or
Examine
.
▪
Full
lets the instrument automatically changes the selected range from one another.
▪
Examine
displays only the selected range.
4
Tap
Configuration
to set up the range table and parameters as below.
Summary of Contents for CellAdvisor 5G
Page 1: ...1 CellAdvisorTM 5G User s Guide ...
Page 2: ......
Page 18: ......
Page 22: ......
Page 110: ......
Page 146: ......
Page 182: ...Using LTE LTE A TDD Analyzer 170 CCDF measurement with LTE LTE A TDD Analyzer ...
Page 264: ......
Page 312: ......
Page 332: ......
Page 338: ......
Page 346: ...Using RFoCPRI Analyzer 334 Rx Settings with RFoCPRI Analyzer ...
Page 352: ......
Page 356: ...Appendix 344 ...
Page 357: ...345 ...
Page 358: ......