Measure the projection of the piston as shown
in the figure, and check the corresponding
value.
-
Ensure that the starter settles at ambient
temperature.
Standard dimension:
Piston length @ 68
°
F (
20
°
C
)
XX-XX in
(
XX-XX mm
)
-
The choke should gradually disengage as it is
being heated electrically.
-
Check the choke resistance at ambient
temperature.
Standard resistance:
Choke resistance @ 68
°
F (
20
°
C
)
~20 O
-
Using a 12V battery, power the automatic choke and check that the piston reaches its
maximum protrusion.
Note:
When performing this check do not generate any short-circuits. It is therefore
necessary to use a cable with suitable terminals.
-
The effective heating time depends on the ambient temperature.
-
If measured projection, resistance or time values are inconsistent with the prescribed
ones, replace the automatic choke assembly.
-
Install the choke onto the carburetor checking
the proper positioning of the O-Ring, insert the
plate with the knurling resting against the
choke and tighten the fixing screw.
-
Orientate the choke device as shown in the
figure.
-
Install the safety casing