10. REMOTE SERVICE
There are following functions as Remote Service.
1. Auto Supply Order
Automatically orders the toner by FAX or E-mail.
2. Service Notification
Notifies the status of the equipment to the service technician by E-mail or FAX.
To start in the self-diagnosis mode, turn OFF the power using the main power switch, then turn ON the
power while two digital keys designated to each mode.
10.1 Auto Supply Order
10.1.1
Outline
Automatically orders the toner.
1. Placing an Order
There are two ways to place an order.
-
FAX
Installation of the FAX board is required.
If the FAX board has not been installed, it is regarded as OFF setting.
-
E-mail (E-mail body + TIFF image)
2. Order Intervals
The Auto Supply Order is sent as indicated in the following steps.
(1)
Toner empty occurs.
(2)
The toner cartridge is replaced.
(3)
The toner empty counter is incremented when the total number of prints or the pixel counter
value exceeds the threshold set in the following self-diagnostic code.
e.g.) When “0” is set for FS-08-6506 and “50” is set for FS-08-6507
The toner empty counter is incremented when 50 sheets are printed after the toner cartridge has
been replaced.
(4)
When the accumulated number of toner empty times reaches the set condition, an order is
placed automatically.
3. If Order Failure Occurs
If some problems occur and the order cannot be placed after registering an order as a job, refer to
the standard countermeasure for the FAX/E-mail transmission failure.
Code
Details
Contents
FS-08-
6506
Toner empty determination counter
Selects the counter to determine toner empty.
0: Output pages
1: Pixel counter
FS-08-
6507
Threshold setting for toner empty
determination (output pages)
Sets the number of output pages to determine toner
empty. This setting is valid when “0” is set at FS-08-
6506.
FS-08-
6508
Threshold setting for toner empty
determination (pixel counter)
Sets the number of the pixel counter value to determine
toner empty. This setting is valid when “1” is set at FS-
08-6506.