8 - 75
[E510] ADU stack jam (paper not reaching the ADU entrance sensor)
Transfer roller
Classification
Error content
Paper transport jam (ADU section)
Jam not reaching the ADU entrance sensor
Proce
dure
Check item
Result
Measure
Next
Step
1
Open the ADU. Is there
any paper in front of the
ADU entrance sensor?
Yes
Remove the paper.
No
2
2
Is the ADU entrance
sensor working? (Perform
the input check in the test
mode: 03-[FAX]OFF/[1]/
[D])
Yes
3
No
•
Check if the connector of the ADU entrance
sensor is disconnected.
•
Check if the connector CN311 on the LGC
board is disconnected.
•
Check if the connector pins are
disconnected and the harnesses are open
circuited.
•
Check if the conductor patterns on the MOT
board and LGC board are short circuited or
open circuited. (e-STUDIO206L/256/306 /
207L/257/307)
•
Check if the conductor patterns on the
MOT2 board and LGC board are short
circuited or open circuited.
(e-STUDIO356/456/506 / 357/457/507)
•
Replace the ADU entrance sensor.
•
Replace the LGC board.
Parts to be replaced