ERROR CODE AND TROUBLESHOOTING
8 - 198
[CB84] Punch unit main program error
[CB90] Paper folding blade motor (M12) abnormality
MJ-1033
Replace parts
Remarks
Saddle control PC board
Classification
Error item
Finisher related service call
Hole Punch Unit - Main CPU program error
Check item
Measures
Hole punch control PC board (HP)
•
Is the firmware version of the PNC board (HP) latest?
•
Connector check
•
Board check
Replace parts
Remarks
Hole punch control PC board
Error
Timing of detection
Paper folding blade motor
Paper folding blade home position
sensor
The turning OFF of the paper folding blade home position
sensor (S19) is not detected in the specified time when the
paper folding blade is pushing while this sensor is ON.
Turning ON of the paper folding blade home position sensor
(S19) is not detected in the specified time when the paper
folding blade is returned to its home position while this sensor is
OFF.
Paper folding blade motor Paper
folding blade motor clock sensor
The status of the paper folding blade motor clock sensor (S24)
is not changed for the specified time when the paper folding
blade motor (M12) is driven.
Probable cause
Checking and measures
Paper folding blade motor (M12)
abnormality
Check if the electrical continuity of the coil is normal. If
electricity is not conducted, replace the motor.
Paper folding blade motor clock
sensor (S24) abnormality
Measure the voltage on TP66 on the finisher control PC board
(FIN). Then check that the measured voltage is 1V or lower
when not shielded and within the range of 3.3V
5% when
shielded. If the voltage does not fall within the range mentioned,
replace the sensor.
Paper folding blade home position
sensor (S19) abnormality
Measure the voltage on TP64 on the finisher control PC board
(FIN). Then check that the measured voltage is 1V or lower
when not shielded and within the range of 3.3V
5% when
shielded. If the voltage does not fall within the range mentioned,
replace the sensor.
Faulty cables and connectors
Check if the electrical continuity between the connector
terminals is normal. If electricity is not conducted, replace the
connectors. (Finisher control PC board (FIN): CN11, CN15)
Finisher control PC board (FIN)
abnormality
If the error still occurs after replacing the motor, sensors and
connectors, exchange the finisher control PC board (FIN).