e-STUDIO2008A/2508A/3008A/3508A/4508A/5008A
© 2015 TOSHIBA TEC CORPORATION All rights reserved
ERROR CODE AND TROUBLESHOOTING
8 - 210
[CC54] Abnormality of paper detection sensors (S24 and S25)
MJ-1032
[CC54] Abnormality of trailing edge detection sensors (S39 and S40) and horizontal registration
detection sensors (S39 and S40)
MJ-1033
Error
Timing of detection
Paper detection sensor (S24/S25)
adjustment error
The adjustment of the paper detection sensors (S24 and S25) has
been failed.
Probable cause
Checking and measures
Paper detection sensors (S24 and
S25) abnormality
Measure the voltage on pin CN6.8 on the hole punch control PC board
(HP). Then check that the measured voltage is 3.0V or higher when
not shielded and 1.2V or lower when shielded. If the voltage does not
fall within the range mentioned, replace a couple of PC boards on
either the light-receiving side or the light-emitting side.
Faulty cables and connectors
Check if the electrical continuity between the connector terminals is
normal. If electricity is not conducted, replace the connector. (Hole
punch control PC board (HP): CN4, CN6)
Hole punch control PC board (HP)
abnormality
If the error still occurs after replacing the sensors and the connectors,
exchange the hole punch control PC board (HP).
Error
Timing of detection
Trailing edge detection sensor
Horizontal registration detection
sensor
After the sensor output adjustment, the input value is lower than
3.2V against the output value of 2.8V, or the input value is
higher than 3.5V against the output value of 0.1V.
Probable cause
Checking and measures
Trailing edge detection sensors
(S39 and S40) abnormality
Measure the voltage on TP48 on the hole punch control PC
board (HP). Then check that the measured voltage is 2.5V or
higher when not shielded and 1V or lower when shielded. If the
voltage does not fall within the range mentioned, replace a
couple of PC boards on either the light-receiving side or the
light-emitting side.
Horizontal registration detection
sensors (S39 and S40)
abnormality (B5-R/ST-R)
Measure the voltage on TP47 on the hole punch control PC
board (HP). Then check that the measured voltage is 2.5V or
higher when not shielded and 1V or lower when shielded. If the
voltage does not fall within the range mentioned, replace a
couple of PC boards on either the light-receiving side or the
light-emitting side.
Horizontal registration detection
sensors (S39 and S40)
abnormality (A4-R/LT-R)
Measure the voltage on TP46 on the hole punch control PC
board (HP). Then check that the measured voltage is 2.5V or
higher when not shielded and 1V or lower when shielded. If the
voltage does not fall within the range mentioned, replace a
couple of PC boards on either the light-receiving side or the
light-emitting side.
Horizontal registration detection
sensors (S39 and S40)
abnormality (B4/LG)
Measure the voltage on TP45 on the hole punch control PC
board (HP). Then check that the measured voltage is 2.5V or
higher when not shielded and 1V or lower when shielded. If the
voltage does not fall within the range mentioned, replace a
couple of PC boards on either the light-receiving side or the
light-emitting side.