6
© 2015 TOSHIBA TEC CORPORATION All rights reserved
e-STUDIO2008A/2508A/3008A/3508A/4508A/5008A
SETTING / ADJUSTMENT
6 - 9
[A] Reproduction ratio of primary scanning direction (Fine adjustment of polygonal motor
rotation speed (Printer))
<Procedure>
(1)
Performs FS-05.
(05 Adjustment Mode)
(2)
Press [1]
[TEST PRINT]. (A grid pattern with 10 mm squares is printed out. Use A3/LD from
the lower drawer (Refer to *).
(3)
Check the grid pattern on the test chart printed out and measure the distance A from the 1st line
to the 21st line of the grid pattern.
(4)
Check if the distance A is within 200±0.5 mm.
(5)
If not, use the following procedure to change values and measure the distance A again.
FS-05
Key in code [4001]
[START]
(Key in a value (acceptable values: 0 to 255))
[OK] (Stored in memory)
“100% A” is displayed
Press [1]
[TEST PRINT]
(A grid pattern is printed out.)
*
The larger the adjustment value is, the longer the distance A becomes (approx. 0.15 mm/
step).
[B] Primary scanning data laser writing start position (Printer)
<Procedure>
(1)
Performs FS-05.
(05 Adjustment Mode)
(2)
Press [1]
[TEST PRINT]. (A grid pattern with 10 mm squares is printed out. Use A3/LD from
the lower drawer (Refer to *).
(3)
Check the grid pattern on the test chart printed out and measure the distance B from the left edge
of the paper to the 6th line of the grid pattern.
(4)
Check if the distance B is within 52±0.5 mm.
(5)
If not, use the following procedure to change values and measure the distance B again.
FS-05
Key in the code [4006]
[START]
(Key in a value (acceptable values: 0 to 255))
[OK] (Stored in memory)
“100% A” is displayed
Press [1]
[TEST PRINT]
(A grid pattern is printed out.)
*
The larger the adjustment value is, the longer the distance B becomes (approx. 0.0423 mm/
step).
(6)
After the adjustment for the code 4006 is completed, apply the same adjustment value for the
code 4005.
FS-05
Key in the code [4005]
[START]
(Key in the same value in the step 5 above)
Press [OK] (Stored in memory).
Notes:
Make sure the first line of the grid pattern is printed out since the line is occasionally vanished.