e-STUDIO2008A/2508A/3008A/3508A/4508A/5008A
© 2015 TOSHIBA TEC CORPORATION All rights reserved
ERROR CODE AND TROUBLESHOOTING
8 - 338
8.4.18
Image dislocation in feeding direction
Fig.8-21
Defective area
Step
Check items
Prescription
Scanner/Printer
adjustment
1
Have the printed images been
dislocated in the same manner?
Adjust the position of the leading
edge of paper in the Adjustment
Mode.
Registration roller
2
Is the registration roller dirty, or the
spring detached?
Clean the registration roller with
alcohol.
Securely attach the springs.
3
Is the registration roller working
properly?
Adjust or replace the gears if they are
not engaged properly.
Feed clutch
4
Is the feed clutch working properly?
Check the circuit or feed clutch, and
replace them if necessary.
Pre-registration guide
5
Is the pre-registration guide installed
properly?
Install the guide properly.
Feeding direction