e-STUDIO2008A/2508A/3008A/3508A/4508A/5008A
© 2015 TOSHIBA TEC CORPORATION All rights reserved
SETTING / ADJUSTMENT
6 - 16
[B] Reproduction ratio adjustment of the primary scanning direction
<Procedure>
(1)
Performs FS-05.
(05 Adjustment Mode)
(2)
Place a ruler on the original glass (along the direction from the rear to the front of the equipment).
(3)
Press [FAX]
[START] to make a copy at the mode of A3/LD, 100% and the lower drawer (refer
to *).
(4)
Measure the distance A from 10 mm to 270 mm of the copied image of the ruler.
(5)
Check if the distance A is within the range of 260±0.5 mm.
(6)
If not, use the following procedure to change values and repeat the steps (3) to (5) above.
FS-05
Key in the code [4000]
[START]
(Key in a value (acceptable values: 0 to 255))
Press the [OK] button (stored in memory).
(“100% A” is displayed.)
*
The larger the adjustment value is, the higher the reproduction ratio and the longer the
distance A become.(approx. 0.1 mm/step)
Fig.6-12
50
100
150
200
250
A
Feeding direction
Copied image of the ruler