e-STUDIO2008A/2508A/3008A/3508A/4508A/5008A
© 2015 TOSHIBA TEC CORPORATION All rights reserved
OUTLINE OF THE MACHINE
3 - 12
3.3
Symbols and Functions of Various Components
The column “P-I” shows the page and item number in the parts list.
3.3.1
Motors
3.3.2
Sensors and switches
Symbol
Name
Function
Remarks
P-I
M1
SCAN-MOT
Scan motor
Driving the carriages
15-8
M2
PU-FAN
Process unit fan
Cooling down the process unit
1-25
M3
POL-MOT
Polygonal motor
Driving the polygonal mirror
11-1
M4
TNR-MOT
Toner motor
Transporting toner from the toner
cartridge to the developer unit
14-29
M5
ADU-MOT
ADU motor
Driving the automatic duplexing unit
8-1
M6
SYS-FAN-MOT
SYS/HDD cooling fan
Cooling down the SYS board and hard
disk
9-3
M7
POW-FAN
Switching regulator cooling fan
Cooling down the High-voltage
transformer and switching regulator
4-14
M8
MAIN-MOT
Main motor
Driving the drum, developer unit, fuser
unit, registration roller, transport rollers,
feed rollers and pickup rollers
14-21
M9
TRU-FAN
TRU fan
Assisting the paper separation process
13-9
M10
EXIT-MOT
Exit motor
Driving the exit roller
33-18
M11
TRAY-U-MOT
Upper tray-up motor
Driving the lifting movement of trays in
upper drawer
7-18
M12
TRAY-L-MOT
Lower tray-up motor
Driving the lifting movement of trays in
lower drawer
7-18
M13
REV-MOT
Reverse motor
Driving the reverse roller
*
35ppm/45ppm/50ppm only
34-22
Symbol
Name
Function
Remarks
P-I
S1
APS1
Automatic original detection sensor-1
Detecting original size
12-12
S2
APS2
Automatic original detection sensor-2
Detecting original size (for LT size)
-
S3
HOME-SNR
Carriage home position sensor
Carriage home position detection
12-5
S4
ATTNR-SNR
Auto-toner sensor
Detecting the density of toner in the
developer unit
28-20
S5
EXIT-SNR
Exit sensor
Detecting the transporting paper at
the exit section
34-2
S6
ADU-TR1-SNR
ADU exit sensor
Detecting the transporting paper in
automatic duplexing unit
35-15