8
© 2015 TOSHIBA TEC CORPORATION All rights reserved
e-STUDIO2008A/2508A/3008A/3508A/4508A/5008A
ERROR CODE AND TROUBLESHOOTING
8 - 211
[CC60, CC61] Punch motor abnormality
MJ-1032
Horizontal registration detection
sensors (S39 and S40)
abnormality (A3/LD)
Measure the voltage on TP44 on the hole punch control PC
board (HP). Then check that the measured voltage is 2.5V or
higher when not shielded and 1V or lower when shielded. If the
voltage does not fall within the range mentioned, replace a
couple of PC boards on either the light-receiving side or the
light-emitting side.
Faulty cables and connectors
Check if the electrical continuity between the connector
terminals is normal. If electricity is not conducted, replace the
connector. (Hole punch control PC board (HP): CN4)
Hole punch control PC board (HP)
abnormality
If the error still occurs after replacing the sensors and the
connectors, exchange the hole punch control PC board (HP).
Error
Timing of detection
Punch motor (M11)
Paper detection sensor (S24/S25)
Punch shaft home position sensor
(S26)
Rear punch shaft home position sensor
(S22)
The paper detection sensors (S24 and S25) do not emit light after
specified time when they are selected
The level of the light-receiving amount is not lowered after the light-
emitting amount of the paper detection sensors (S24 and S25) is
adjusted to the lower limit.
Punching is not performed after punching request is sent, or the
punching request is sent during the punching.
The status of the punch shaft home position sensor (S26) or the rear
punch shaft home position sensor (S22) is not changed after punching
request is sent.
A punching locking signal is detected consistently over the specified
time.
The punch shaft home position sensor (S26) or the rear punch
shaft home position sensor (S22) does not detect that the shaft
is not at its home position at the start of punching or punch
waste full detection.
Probable cause
Checking and measures
Punch motor (M11) abnormality
Check if the electrical continuity of the coil is normal. If electricity is not
conducted, replace the motor.
Rear punch shaft home position sensor
(S22) abnormality
Measure the voltage on TP25 on the hole punch control PC board
(HP). Then check that the measured voltage is 1V or lower when not
shielded and within the range of 5V
5% when shielded. If the
voltage does not fall within the range mentioned, replace the
sensor.
Punch shaft home position sensor
(S26) abnormality
Measure the voltage on TP24 on the hole punch control PC board
(HP). Then check that the measured voltage is 1V or lower when not
shielded and within the range of 5V
5% when shielded. If the
voltage does not fall within the range mentioned, replace the
sensor.
Punch motor clock sensor (S20)
abnormality
Measure the voltage on TP27 on the hole punch control PC board
(HP). Then check that the measured voltage is 1V or lower when not
shielded and within the range of 5V
5% when shielded. If the
voltage does not fall within the range mentioned, replace the
sensor.
Faulty cables and connectors
Check if the electrical continuity between the connector terminals is
normal. If electricity is not conducted, replace the connector. (Hole
punch control PC board (HP): CN2, CN5, CN6)
Probable cause
Checking and measures