8.4.22
Blotched image
Fig.8-25
Defective area
Step
Check items
Prescription
Paper
1
Is the paper type corresponding to its
mode?
Check the paper type and mode.
2
Is the paper too dry?
Change the paper.
Transfer roller unit
3
Is the power supplying spring of the
transfer roller installed securely? (Is it
almost detached?)
Check the power supplying spring
and reinstall it.
High-voltage transformer
(Transfer roller unit)
4
Is the output from the high-voltage
transformer normal?
Adjust the output. Replace the
transformer if necessary.
Separation
5
Is the output from the separation
charger too high?
Adjust the output, from the
separation charger.
Feeding direction