Notes:
•
When removing the flat cable [3], change the
lever position so that the connector is
released, and remove the flat cable by lifting
it up slightly (approx. 7 degrees) as shown in
the right figure.
•
When connecting the flat cable [3] to the
connector, insert the flat cable straightly and
lock it securely. Confirm that the tabs are in
the positions shown in the right figure.
Fig. 9-3
Notes:
•
When installing the flat cable [3], do not push
it in strongly.
•
When installing the flat cable [3], be careful
not to insert it at an angle.
•
Do not apply pressure to or damage the
edge of the flat cable [3].
Fig. 9-4
(6)
Disconnect 10 connectors from the SYS
board. Remove 2 flat cables [4].
Fig. 9-5