ERROR CODE AND TROUBLESHOOTING
8 - 327
8.4.8
Solid copy
Fig.8-10
Defective area
Step
Check items
Prescription
Exposure lamp and
inverter / LED board
1
Does the exposure lamp light?
Check if the connector contacts with
the exposure lamp terminal.
Replace the defective inverter / LED
board (e-STUDIO206L/256/306/356/
456/506 only).
Scanner
2
Is there any foreign matter on the
light path?
Remove it.
Bedewed scanner and
drum
3
Is the scanner or drum bedewed?
Clean the mirrors, lens and drum.
Keep the power cord plugged in all
trough the day and night.
(For the model with damp heater)
Main charger
4
Is the main charger securely
installed?
Install it securely.
5
Is the needle electrode broken?
Replace the needle electrode.
High-voltage transformer
(Main charger)
6
Is the high-voltage transformer
output defective?
Adjust the output, or replace the
transformer.
7
Are the connectors of the high-
voltage harness securely connected?
Is the harness open circuited?
Reconnect the harness securely.
Replace the high-voltage harness.
CCD, SLG, SYS, LGC
boards and harnesses
8
Are the connectors securely
connected?
Check if the harnesses connecting
the boards are open circuited.
Connect the connectors securely.
Replace the harness.
Feeding direction