e-STUDIO2008A/2508A/3008A/3508A/4508A/5008A
© 2015 TOSHIBA TEC CORPORATION All rights reserved
SETTING / ADJUSTMENT
6 - 40
6.7
Image Quality Adjustment (FAX Function)
6.7.1
Density adjustment
The center density and the density variation controlled by density adjustment keys can be adjusted as
follows.
<05 Adjustment Mode>
*
Since the gradation in this mode is reproduced in a binary image (black and white), this adjustment
should be a simple binary threshold adjustment.
<Procedure>
(1)
Performs FS-05.
(2)
Key in a code and press the [START] button.
(3)
Key in an adjustment value.
(To correct the value once keyed in, press the [CLEAR] button.)
(4)
Press the [OK] button to store the value.
The equipment goes back to the ready state.
(5)
To set it again, repeat step (2) to (4).
(6)
Turn the power OFF.
<Confirmation>
If possible, perform a Fax transmission and check the adjusted density with the image on the recipient's
side.
Color
mode
Original mode
Item to be
adjusted
Remarks
Text/
Photo
Text *
Photo
Black
7533
7534
7535
Manual density
center value
The larger the value is, the darker the image
becomes.
Acceptable values: 0 to 255 (Default: 128)
7542
-
7543
Automatic density
mode