4.5.4
Paper size detection board
Notes:
When replacing the parts or performing
machine refreshment, apply 1 rice-sized
grain of white grease (Molykote HP-300) to
the bushings [2] of the bypass separation
roller.
Fig. 4-112
(1)
Open the bypass tray [1] and pull out the
slide tray [2].
Fig. 4-113
(2)
Remove 1 screw from back side of the
bypass tray. Take off the paper size detection
board cover [3].
Fig. 4-114
[2]