8
© 2015 TOSHIBA TEC CORPORATION All rights reserved
e-STUDIO2008A/2508A/3008A/3508A/4508A/5008A
ERROR CODE AND TROUBLESHOOTING
8 - 159
[C262] Communication error between the CCD board and the SYS board (e-STUDIO207L/257/
307/357/457/507)
[C270] Carriage home position sensor not going OFF within a specified time (e-STUDIO206L/
256/306/356/456/506)
Remove the original glass and move the carriages to the paper feeding side. Turn ON the power and
check the following items.
Classification
Error content
Scanning system related service
call
Peak detection error (the light source is extremely light)
Proce
dure
Check item
Measure
1
Lens unit
1. Check if the connector is properly connected all the way in
the CCD board.
2. Check if there is any abnormality in the appearance of parts
mounted on the CCD board.
3. Check if +5V is output to the lens unit.
4. Check if +3.3V is output from IC9. Check if +1.8V is output
from IC11.
5. Replace the Lens unit.
2
SYS board
1. Check if the connector is properly connected all the way in
the SYS board.
2. Check if there is any abnormality in the appearance of parts
mounted on the SYS board.
3. Check if +5V is output to the SYS board.
4. Replace the SYS board.
3
Harnesses
1. Check if the harness has any scratch on it or is open
circuited or caught anywhere.
2. Check if there is any abnormality in the connector terminal
or the contacting surface of the flat harness.
3. Replace the harness between the SYS board and the CCD
board.
Parts to be replaced
Remark
Lens unit
SYS board
Harnesses
Classification
Error content
Scanning system related service
call
The carriage does not shift from its home position in a specified
period of time.
Check item
Measure
1
Carriage locking
Check if the carriage locking screw for packaging is attached.
2
Carriage home position
sensor
1. Check if the harness of the carriage home position sensor is
connected properly.
2. Check if the harness is caught or open circuited.