8
© 2015 TOSHIBA TEC CORPORATION All rights reserved
e-STUDIO2008A/2508A/3008A/3508A/4508A/5008A
ERROR CODE AND TROUBLESHOOTING
8 - 79
[EB50] Paper left on the transport path due to multiple feeding
When the paper is fed from the upper drawer:
Classification
Error content
Paper transport jam
The multiple feeding of preceding paper caused the misfeeding of
upcoming paper.
Proce
dure
Check item
Result
Measure
Next
Step
1
ADU
Open the ADU and remove paper if there is
any on the transport path.
2
2
Is the registration sensor
working? (Perform the
input check: 03-[FAX]/ON/
[9]/[A])
Yes
Check the rollers. Replace them if they are
worn out
No
3
3
LGC board
1. Check if the connector CN316 on the LGC
board is disconnected.
2. Check if the connector pins are
disconnected or the harnesses are open
circuited.
3. Check if the conductor patterns on the LGC
board are short circuited or open circuited.
Parts to be replaced
Remark
Registration sensor
LGC board
Rollers on the transport path