e-STUDIO2008A/2508A/3008A/3508A/4508A/5008A
© 2015 TOSHIBA TEC CORPORATION All rights reserved
SETTING / ADJUSTMENT
6 - 44
(4)
Install the high-voltage transformer jig and fix
it with 2 screws.
Notes:
Be careful not to let the connector and the
harness be caught.
Fig.6-21
(5)
Fix the green cable of the high-voltage
transformer jig to the frame of the equipment.
Fig.6-22
(6)
Install the door switch jig.
(7)
Take off the transfer roller unit.
(8)
Close the automatic duplexing unit.
Fig.6-23
Process unit
Green cable
Door switch jig