e-STUDIO2008A/2508A/3008A/3508A/4508A/5008A
© 2015 TOSHIBA TEC CORPORATION All rights reserved
SETTING / ADJUSTMENT
6 - 86
[ 2 ] Resetting procedure
The setting values which are set in
P. 6-80 "[ 1 ] Adjusting procedure"can be reset with the following
steps.
(1)
Turn OFF the power of the equipment.
(2)
Remove 1 screw and take off the board access cover.
(3)
Set the SW1 on the Finisher control board as shown in the figures below.
Fig.6-89
(4)
Turn ON the power of the equipment while pressing the [FUNCTION CLEAR] button and
[START] button simultaneously.
(5)
Press [Button1] 11 times, press [Button2] once, press [Button1] 11 times, and then press
[Button2] once.
(6)
Press [Button1] and [Button2] simultaneously.
(7)
Turn OFF the power of the equipment.
(8)
Turn OFF all bits of SW1 on the Finisher control board as shown below.
Fig.6-90
(9)
Install the board access cover with 1 screw.
ON
SW1
1
2
3
4
SW1
[1]
ON SW1
1
2
3
4
ON SW1
1
2
3
4