4
© 2015 TOSHIBA TEC CORPORATION All rights reserved
e-STUDIO2008A/2508A/3008A/3508A/4508A/5008A
DISASSEMBLY AND REPLACEMENT
4 - 197
4.13.12 MJ-5015 (Job Separator) <35ppm/45ppm/50ppm>
(7)
Loosen 2 screws and take off the front cover
of MJ-5014.
Fig. 4-540
(8)
Remove 1 screw. Lift up the job separator
and release the hook. Take off the job
separator toward the front.
Fig. 4-541
(1)
Press the [Power] button on the control panel
to shut it down.
(2)
Turn the main power switch of the equipment
off.
(3)
Disconnect the power cable.
(4)
Remove the tray.
Fig. 4-542