6
© 2015 TOSHIBA TEC CORPORATION All rights reserved
e-STUDIO2008A/2508A/3008A/3508A/4508A/5008A
SETTING / ADJUSTMENT
6 - 51
6.9.2
Position adjustment of CCD lens unit
Count the number of lines and write it down for later reference before removing the CCD lens unit.
When installing the CCD lens unit, the same number of lines needs to be visible.
P. 4-19 "4.3.4 Lens unit/CCD driving PC board"
6.9.3
Belt tension adjustment of the Scan motor
(1)
Take off the rear cover.
(2)
Hook the belt tension jig[1] to the motor
bracket[2] and hook section of the flame[3].
(3)
Loosen the screws [4] and [5].
(4)
The scan motor [6] is pulled by the belt
tension jig [1]. When it is stopped, tighten the
screws in order of [4] and [5].
(5)
Remove the belt tension jig[1].
Fig.6-31
Fig.6-32
[5]
[2]
[4]
[6]
[1]
[3]