e-STUDIO2008A/2508A/3008A/3508A/4508A/5008A
© 2015 TOSHIBA TEC CORPORATION All rights reserved
SETTING / ADJUSTMENT
6 - 24
6.4.2
Density adjustment
The center density and the density variation controlled by density adjustment keys can be adjusted as
follows.
< 05 Adjustment Mode >
Make a test copy and compare the image obtained with the current settings; if necessary, make
adjustment using the following procedure.
<Procedure>
(1)
Performs FS-05.
(2)
Key in a code and press the [START] button.
(3)
Key in an adjustment value.
(To correct the keyed-in value, press the [CLEAR] button.)
(4)
Press the [OK] button to store the value.
The equipment goes back to the ready state.
(5)
Press the [TEST COPY] button and then the [START] button. Then perform test copying.
(6)
If the desired image density has not been attained, repeat step (1) to (5).
Original mode
Item to be adjusted
Remarks
Text/
Photo
Photo
Text
User Custom
7114
7116
7115
7134
Manual density mode
center value
The larger the value is, the
darker the image becomes.
Acceptable values: 0 to
255 (Default: 128)
7123
7125
7124
7137
Automatic density
mode
The larger the value is, the
darker the image becomes.
Acceptable values: 0 to 255
(Default: 128)