9
© 2015 TOSHIBA TEC CORPORATION All rights reserved
e-STUDIO2008A/2508A/3008A/3508A/4508A/5008A
REPLACEMENT OF PC BOARDS/HDD
9 - 19
9.2.4
Precautions and procedures when replacing the SYS board
A procedure for SYS board replacement is shown below.
Fig. 9-29
Notes:
[C] and [D] are required only for the equipment in which the ADI-HDD has been installed.
[A] Return License
Notes:
•
If the 08 Setting Mode is not started up, "[A]Return License" can be omitted. In that case,
reinstall the license with "[ 1 ]Re-registration when the board is replaced" if it is cleared since
"[H] Reinstallation of License" cannot be performed.
•
When installing the Data Overwrite Enabler (GP-1070) and security mode is setting High
Security, set the security mode levlel to "1" (Low level). Then restart the equipment.
(1)
Key in [3840], and then press the [ENTER].
(2)
Select the license to be returned, and then press the [REMOVE].
(3)
Install the one-time dongle, which you used for uploading the selected license, in the equipment,
and then press the [OK].
[F] Update firmware version
Start
[A] Return License
[C] Restore ADI key
[H] Reinstall license
[E] Restore license
[I] Check firmware versions
[D] Restore encryption key
Setting completed
[G] Data transfer of characteristic value of scanner
[B] Replace the SYS board