e-STUDIO2008A/2508A/3008A/3508A/4508A/5008A
© 2015 TOSHIBA TEC CORPORATION All rights reserved
ERROR CODE AND TROUBLESHOOTING
8 - 166
8.3.12
Process related service call
[C3D0] EPU board memory overwriting error
[C3D1] EPU board memory new parts detection error
Classification
Error content
Process related service call
EPU board memory overwriting error
Check item
Measure
Process unit
Check if the process unit is properly installed, and check if the
connector pins that are connected to the equipment are
disconnected or have any abnormality such as deformation.
EPU memory board
Check if the harness connected to the connector J451 on the
EPU board has any abnormality.
Parts to be replaced
Remark
EPU memory board
LGC board
Classification
Error content
Process related service call
EPU board memory new parts detection error
Check item
Measure
Process unit
1. If the process unit has been replaced with a new one before
the equipment is started, turn the power OFF and then back
ON in the EPU replacement mode ([7] + [START]).
2. If the process unit has not been replaced, check the
following.
3. Check if the process unit is properly installed, and check if
the connector pins that are connected to the equipment are
disconnected or have any abnormality such as deformation.
4. Check if the harness connected to the connector J451 on
the EPU board has any abnormality.
Parts to be replaced
Remark
EPU memory board
LGC board