PREVENTIVE MAINTENANCE (PM)
7 - 17
7.7.1
Scanner
Fig. 7-7
*
a, b. Original glass/ADF original glass
Clean both sides of the original glass and ADF original glass.
Notes:
Make sure that there is no fingerprints or oil staining on part of the original glass on where the
original scale is mounted since the shading correction plate is located below the scale to be
scanned.
Items to check
Cleaning
Lubrication
Replacement
(x 1,000 sheets)
Operation
check
Parts list
<P-I>
a
Original glass
A or B
22-3
b
ADF original glass
B
22-1
c
Mirror 1
B
d
Mirror 2
B
e
Mirror 3
B
f
Reflector
B
23-5
g
Lens
B
12-13
h
Exposure lamp
R3
23-3
i
Automatic original
detection sensor
B
12-16
j
Slide sheet
(front and rear)
B
R3
15-1
a
g
i
c
j
f
h
b
d
e