8
© 2015 TOSHIBA TEC CORPORATION All rights reserved
e-STUDIO2008A/2508A/3008A/3508A/4508A/5008A
ERROR CODE AND TROUBLESHOOTING
8 - 183
8.3.19
Finisher related service call
[CB00] Finisher not connected
[CB01] Finisher communication error
[CB01] Finisher communication error
MJ-1033
[CB10] Entrance motor abnormality
MJ-1101/1107
Classification
Error content
Finisher related service call
Finisher not connected
Finisher communication error
Check item
Measure
Setting of the equipment
•
Check if the MJ-1101/1107, MJ-1106/1108, MJ-1032 or MJ-1033
is set as the specified finisher on the equipment (08-4548).
Finisher
•
Check if the harness connecting the equipment and the finisher
controller PC board is disconnected or open circuited.
•
Check if the conductor pattern on the finisher controller PC
board is open circuited or short circuited.
•
Update the finisher firmware.
Converter
•
Check if the connector connecting the converter board and the
LGC board on the equipment is disconnected or open circuited.
•
Check if the conductor pattern on the converter PC board is
open circuited or short circuited.
•
Update the converter firmware.
Parts to be replaced
Remark
Converter board
Finisher control PC board
Error
Timing of detection
Data communication error
The communication between the equipment and the Finisher is
interrupted. This error is detected by the equipment.
Classification
Contents
Finisher related service call
Entrance motor abnormality: The entrance motor is not rotating
normally.
Check Item
Measure
Entrance roller
If there is mechanical problem when the entrance roller is
rotated, fix the mechanism.
Entrance motor (M1)
Check the connectors and harnesses between the entrance
motor (M1) and the finisher control PC board (CN7).
Replacement part
Measure
Entrance motor (M1)
Finisher controller PC board