e-STUDIO2008A/2508A/3008A/3508A/4508A/5008A
© 2015 TOSHIBA TEC CORPORATION All rights reserved
DISASSEMBLY AND REPLACEMENT
4 - 148
4.11.9
Reverse roller <35ppm/45ppm/50ppm>
Notes:
When replacing the the idling roller or idling
roller shaft, apply 0.5 x 2 rice-sized grain of
white grease (Molykote EM-30L) to each oil
groove [8] and [9].
Fig. 4-396
(1)
Remove the reverse motor unit.
P. 4-144 "4.11.6 Reverse motor (M13)
(2)
Remove the 1 gear [1], 1 clip [2], 1 bushing
(metal) [3], and 1 bushing (resin) [5], then
take off the reverse roller [4].
Fig. 4-397
Fig. 4-398
[8]
[9]
[2]
[5]
[4]