e-STUDIO2008A/2508A/3008A/3508A/4508A/5008A
© 2015 TOSHIBA TEC CORPORATION All rights reserved
ERROR CODE AND TROUBLESHOOTING
8 - 202
[CBE0] Saddle Stitch Finisher folding motor (M17) abnormality
MJ-1106/1108
*
You receive a [CBE0] error when the [EF17] error occurs three times in succession.
[CBF0] Stacker motor (M9) abnormality
MJ-1033
Saddle stitch alignment plate home
position sensor (S20) abnormality
Measure the voltage on pin CN16.12 on the finisher control PC
board (FIN). Then check that the measured voltage is 1V or
lower when not shielded and within the range of 3.3V
5% when
shielded. If the voltage does not fall within the range mentioned,
replace the sensor.
Faulty cables and connectors
Check if the electrical continuity between the connector
terminals is normal. If electricity is not conducted, replace the
connectors. (Finisher control PC board (FIN): CN6, CN16)
Finisher control PC board (FIN)
abnormality
If the error still occurs after replacing the motor, sensor and
connectors, exchange the finisher control PC board (FIN).
Classification
Contents
Finisher related service call
An encoder pulse interruption error or rotation abnormality
occurs in the saddle stitch finisher folding motor.
Check Item
Measure
Folding motor encoder sensor
(S34)
•
Sensor check (S34)
•
Connector check
•
Harness check
Side alignment motor (M15)
Harness check
Saddle control PC board (SDL)
•
Connector check (CN11, CN14)
•
Board check
Replacement part
Measure
Folding motor encoder sensor
(S34)
Side alignment motor (M15)
Saddle control PC board (SDL)
Error
Timing of detection
Stacker motor
Stacker home position sensor
The turning OFF of the stacker home position sensor (S21) is
not detected in the specified time when the stacker is moved
from a point where this sensor is turned ON to one point where
this sensor is turned OFF.
The turning ON of the stacker home position sensor (S21) is not
detected in the specified time when the stacker is moved from a
point where this sensor is turned OFF to one point where this
sensor is turned ON.
Probable cause
Checking and measures
Stacker motor (M9) abnormality
Check if the electrical continuity of the coil is normal. If electricity is not
conducted, replace the motor.
Stacker home position sensor (S21)
abnormality
Measure the voltage on pin CN16.15 on the finisher control PC board
(FIN). Then check that the measured voltage is 1V or lower when not
shielded and within the range of 3.3V
5% when shielded. If the voltage
does not fall within the range mentioned, replace the sensor.
Probable cause
Checking and measures