e-STUDIO2008A/2508A/3008A/3508A/4508A/5008A
© 2015 TOSHIBA TEC CORPORATION All rights reserved
ERROR CODE AND TROUBLESHOOTING
8 - 340
8.4.20
Poor cleaning
Fig.8-23
Defective area
Step
Check items
Prescription
Developer material
1
Using the specified developer
material?
Use the specified developer material
and toner.
Cleaner
2
Is the cleaning blade in proper
contact with the drum?
Check the cleaning blade.
3
Has the cleaning blade been turned
up?
Replace the cleaning blade.
Check and replace drum if
necessary.
Toner recovery auger
4
Is the toner recovered normally?
Clean the toner recovery auger.
Check the pressure of the cleaning
blade.
Check if the toner recovery auger is
rotated properly.
Fuser unit
5
Are there bubble-like scratches on
the fuser roller (94 mm pitch on the
image), (110mm: e-STUDIO356/456/
506 / e-STUDIO357/457/507)?
Replace the fuser roller. Check and
adjust the temperature control circuit.
6
Has the fuser roller reached its PM
life?
Replace the fuser roller.
7
Is the pressure of the fuser roller
normal?
Check and adjust the mechanism.
8
Is the setting temperature of the fuser
roller normal?
Check the setting and correct it.
08-2009, 2010, 2101, 2120, 2140
(08-5285: e-STUDIO356/456/506 / e-
STUDIO357/457/507)
Feeding direction