ERROR CODE AND TROUBLESHOOTING
8 - 209
[CC52] Skew adjustment motor (M1) abnormality
MJ-1101/1106 (when MJ-6103 is installed), MJ-1107/1108 (when MJ-6104 is installed)
*
The [CC52] error occurs when the [ED10] error occurs three times in succession or during the initial
operation.
[CC53] Punch waste full sensors (S41 and S42) abnormality
MJ-1033
Faulty cables and connectors
Check if the electrical continuity between the connector
terminals is normal. If electricity is not conducted, replace the
connector. (Hole punch control PC board (HP): CN5, CN7)
Hole punch control PC board (HP)
abnormality
If the error still occurs after replacing the motor, sensor and
connectors, exchange the hole punch control PC board (HP).
Classification
Contents
Finisher related service call
Skew adjustment motor (M1) abnormality: Skew adjustment
motor is not rotating or puncher is not shifting normally.
Check Item
Measure
Transport path
If there is any paper remaining on the transport path, remove
the paper.
Skew adjustment motor (M1)
•
If there is mechanical problem when the skew adjustment
motor (M1) is rotated, fix the mechanism.
•
Check the connectors and harnesses between the hole
punch control PC board (HP) and skew adjustment motor
(M1).
Skew home position sensor (S2)
•
Sensor check
•
Harness check
Replacement part
Measure
Skew home position sensor (S2)
Skew adjustment motor (M1)
Hole punch control PC board (HP)
Error
Timing of detection
Punch waste full sensor
After the sensor output adjustment, the input value is lower than
1.2V against the output value of 2.8V, or the input value is
higher than 1.5V against the output value of 0.1V.
Probable cause
Checking and measures
Punch waste full sensors (S41 and
S42) abnormality
Measure the voltage on TP49 on the hole punch control PC
board (HP). Then check that the measured voltage is 1V or
lower when not shielded and 2.5V or higher when shielded. If
the voltage does not fall within the range mentioned, replace a
couple of PC boards on either the light-receiving side or the
light-emitting side.
Faulty cables and connectors
Check if the electrical continuity between the connector
terminals is normal. If electricity is not conducted, replace the
connector. (Hole punch control PC board (HP): CN5)
Hole punch control PC board (HP)
abnormality
If the error still occurs after replacing the sensors and the
connectors, exchange the hole punch control PC board (HP).
Probable cause
Checking and measures