6
© 2015 TOSHIBA TEC CORPORATION All rights reserved
e-STUDIO2008A/2508A/3008A/3508A/4508A/5008A
SETTING / ADJUSTMENT
6 - 65
[B] Adjustment
Simplex copying:
(1)
Shift the aligning plate with the scale as the guide shown in the figure below to adjust the skew.
Fig.6-65
(2)
If the image skew is “C” as shown in the figure below, shift the aligning plate in the direction of
“+”, and if “D”, shift it to “-”.
Fig.6-66
Fig.6-67
Shift the aligning plate in the direction of “+”.
Shift the aligning plate in the direction of “-”.
C
D