Chapter 4
84
Using a Remote Control Device Interface
Master Controller (MC) Commands
The MC command affects
the TDR7 master controller functions, including the remote control
interface, the non–volatile configuration and program memory, and
other TDR7 control functions.
MC Command List
First Level
Mnemonic
Second Level
Mnemonic
Third Level
Mnemonic
Effected Functions
RS232 (0)
RS–232 remote control port configuration
BAUD (1)
Asynchronous interface baud rate
1200
1200 baud (DVB default)
2400
2400 baud
4800
4800 baud
9600
9600 baud
19200
19200 baud
38400
38400 baud
PARITY (2)
Parity
N
No parity (DVB default)
O
Odd parity
E
Even parity
DATA (3)
Number of data bits
7
7 data bits
8
8 data bits (DVB default)
STOP (4)
Number of stop bits
1
1 stop bit (DVB default)
2
2 stop bits