165
© Tieline Research Pty. Ltd. 2020
Genie Distribution WNET Manual v3
Calls are answered based on the
POTS Answer settings
in
Config 1
&
2
. Adjustments to
these
Config
settings are not normally necessary when connecting between Tieline codecs.
They are usually adjusted when connecting to non-Tieline codecs over POTS (see
5. Click the
Max Bitrate
drop-down arrow to adjust the maximum bit rate (dialing and answering).
The default setting is
28800
(28.8kbps) and this only affects
POTS Codec
calls. The range of
the setting is 9.6kbps to 33.6kbps. Even if the line is capable of establishing a connection at a
higher bit rate, the
Max Bitrate
setting is the highest bit rate that will be attempted. Reducing
this value can improve connection reliability on poor quality lines. If two codecs are not
configured with the same setting, they will attempt to connect at the lowest of the two
Max Bit
rate
settings.
Important Note:
G5 POTS modems initially attempt to establish a link at the lowest
Max Bitrate
setting configured in the two modules being connected. If the POTS line
doesn't support this bit rate, the modems will attempt to connect at the highest possible
bit rate to suit the prevailing line quality at each end of the link.
6. Click the drop-down arrow for
Dialing Method
to select
Tone
(DTMF) or
Pulse
dialing over
POTS Codec connections. Tone dialing is used always when the
Answer Mode
is
Analog
Phone
.
7. Click the drop-down arrow for
Dial Tone Detect
to select either:
·
Wait for Dial Tone
: The module will only be allowed to dial when a dial tone is present
on the line.
·
Blind Dialing
: Allows the module to dial when no dial tone is present.