170
Genie Distribution WNET Manual v3
© Tieline Research Pty. Ltd. 2020
Adjusting Audio Levels
To adjust input audio levels, click on the input slider and drag it to the desired input gain level.
Alternatively, click the arrows below a PPM meter to incrementally increase or decrease the input
level in 0.5dB steps. Input levels on the
Input
panel
should be set to ensure audio peaks average at
the first yellow indications on the PPM meters, which represents nominal 0 VU at -18dBFS. Audio
levels should also be verified using the meters in the
PPMs
panel
.
Important Notes:
There is a maximum of 6dB of additional gain available when adjusting a
digital input.
Changing the Input PPM Meter Units from dBFS to dBU
It is also possible to switch the analog input PPM meter unit of measurement from dBFS
(default) to dBU:
1. Open the HTML5 Toolbox Web-GUI and click
Settings
in the
Menu Bar
, then click
Options
to display the
Options panel
.
2. Select
Audio
and then click
Edit
.
3. Click the
Analog Inputs PPM Units
drop-down menu and select
dBU
, then click
Save
.
Configuring Input Settings
Selecting Analog and Digital Audio Sources
Codec inputs are configured for
WNet
digital sources by default.
1. Click the
Input Settings
symbol.
2. Select
Type
and then
Analog
or
WNet
.
3. Click
Save
to confirm the new setting.