
259
© Tieline Research Pty. Ltd. 2020
Genie Distribution WNET Manual v3
2. Enter the name of the audio stream connection in the text box and click
Next
.
3. Configure the transport settings for this connection:
For IP click the drop-down
Session Protocol
menu and select
Tieline Codecs
and
ensure the
Any
check-box is not selected, then click
Next
.
Local Audio Port 9010
is used by default for a second IP connection.
Click to configure:
·
Auto Jitter Adapt
and the preferred auto jitter setting using the drop-down arrow for
Buffer priority
. It is also possible to configure the
Minimum depth
and
Maximum
depth
of jitter over the connection. See
·
Alternatively, select a
Fixed Buffer Level
and enter the
Jitter Depth
, which must
be between 12ms and 5000ms depending on the algorithm you select.